My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0013292
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LEGACY
>
255
>
2600 - Land Use Program
>
PA-2000073
>
SU0013292
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2021 10:52:59 AM
Creation date
5/13/2020 4:51:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0013292
PE
2634
FACILITY_NAME
PA-2000073
STREET_NUMBER
255
Direction
W
STREET_NAME
LEGACY
STREET_TYPE
DR
City
MOUNTAIN HOUSE
Zip
95391-
APN
25423003
ENTERED_DATE
5/13/2020 12:00:00 AM
SITE_LOCATION
255 W LEGACY DR
RECEIVED_DATE
5/8/2020 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i ) All service , trash , storage areas , and utility equipment shall be screened from public view utilizing <br /> a combination of planting and architectural elements that are consistent with the project <br /> architecture . ( Mountain House Commercial , Office and Industrial Design Manual , Chap . 3 , Pg . 21 ) <br /> ii ) Walls used for screening shall be a minimum of six inches higher than the item/area being <br /> screened . ( Mountain House Commercial , Office and Industrial Design Manual . , Chap . 3 , Pg . 21 ) <br /> iii ) Refuse collection and storage shall be located to the rear and sides of buildings , covered with a <br /> roof , and sized to contain all refuse generated on site between collections . ( Mountain House <br /> Commercial , Office and Industrial Design Manual . , Chap . 3 - 21 ) <br /> Timing : Improvement Plans , Building Permits . <br /> k) ACCESS AND CIRCULATION : The following requirements apply and shall be shown on the Site <br /> Plan : <br /> i ) Access driveways shall have a width of no less than twenty-four ( 24) feet for two -way aisles and <br /> sixteen ( 16 ) feet for one -way aisles , except that in no case shall driveways designated as fire <br /> department access be less than twenty ( 20 ) feet wide . ( Development Title Section 9 - <br /> 1015 . 5M [g ] [ 1 ] ) <br /> ii ) The design of the driveway access and traffic circulation plan for the site shall be incorporated into <br /> the construction plans . <br /> Timing : Improvement Plans , Building Permits . <br /> 1 ) LIGHTING : All off- street parking areas within commercially- zoned projects , and projects where the <br /> parking area is used at night , shall be provided with exterior lighting which meets the following <br /> standards : <br /> i ) Parking lot luminaries shall be metal halide with ninety ( 90 ) degree cut- off and flat lenses , unless <br /> specified differently in the applicable Mountain House Design Manual . ( Development Title Section <br /> 9 - 1015 . 5M [f] [ 1 ] ) <br /> ii ) Any lighting shall be designed to confine direct rays to the premises . No spillover beyond the <br /> property lines shall be permitted except onto public thoroughfares , provided , however , that <br /> such light shall not cause a hazard to motorists . ( Development Title Section 9 - 1015 . 5 [g ] [4] ) <br /> Timing : Improvement Plans , Building Permits . <br /> m ) SIGNS : Sign details shall be consistent with Chapter 9 - 1710 of the Development Title and be included <br /> on the Site Plan . All portions of any sign shall be set back a minimum of five ( 5 ) feet from any future <br /> right- of-way line , including any corner cut- off ( snipe ) . ( Development Title Section 9 - 1710 . 2 [g ] ) <br /> n ) BUILDING CODE REQUIREMENTS : The following California Building Code ( CBC ) and San <br /> Joaquin County Ordinance requirements will be applicable to the proposed project . The following <br /> conditions shall be addressed prior to submittal of a building permit application to the Building <br /> Inspection Division : <br /> i ) A building permit for each separate structure or building is required . Submit plans , <br /> specifications and supporting calculations , prepared by a Registered Design Professional <br /> ( architect or engineer) for each structure or building , showing compliance with The 2016 <br /> California Building , Existing Building , Mechanical , Plumbing , Electrical , Energy and Fire <br /> Codes as may be applicable . Plans for the different buildings or structures may be combined <br /> PA- 2000073 — Conditions of Approval 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.