PR0513643
PE
2227
FACILITY_ID
FA0003769
FACILITY_NAME
TERESI TRUCKING LLC
STREET_NUMBER
900
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04905026
CURRENT_STATUS
01
SITE_LOCATION
900 1/2 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED BY SJCEHD (EF) on 5/6/2020 <br /> AdvancedGeo <br /> Environmental <br /> 20 December 2019 <br /> AGE Project No. 15-3508 <br /> Ms. Elianna Florido <br /> Registered Environmental Health Specialist <br /> San Joaquin County Environmental Health Department <br /> 1868 East Hazelton Avenue <br /> Stockton, California 95205 <br /> Subject: Aboveground Storage Tank (AST) Integrity Assessment Amendment <br /> TERESI FACILITY <br /> 900 % Victor Road, Lodi, California <br /> Dear Ms. Florido: <br /> On behalf of Teresi Trucking, Advanced GeoEnviron mental. Inc_ (AGE) has prepared this <br /> Aboveground Storage Tank (AST) Integrity Assessment Amendment to correct the <br /> discrepancies and non-compliant issues noted within the 15 May 2019 Aboveground <br /> Storage Tank Integrity Assessment Report_ <br /> It was noted in the assessment report that the 800-gallon waste oil AST was observed <br /> without a visual and audible overfill alarm system during the time of the integrity testing <br /> and inspection. In response to recommendations made within the report, the San Joaquin <br /> County Environmental Health Department(SJCEHD) require that an overfill alarm system <br /> be installed on the waste oil AST, per Title 22 CCR section 66265.192(k). <br /> In order to operate the waste oil AST in compliance, Teresi Trucking obtained Donlee <br /> Pump Company in October 2019, to install a Husky 007 Audible and Visual Tank Gauge <br /> system. The gauge includes an indoor mount control panel, remote tank sensor, 10' lead <br /> wire and 12-volt transformer. <br /> AGE has determined that the installed audible and visual tank alarm system is sufficient <br /> and has been approved by the Professional Engineer (PE). This amendment overrides <br /> Section 2.2 and Section 6.0 of the original integrity report dated 15 May 2019. This letter <br /> report will be included with the original report and kept within the SPCCP binder for the <br /> life of the plan. <br /> ` , <br /> 837 Shave Road • Stockton,CA 95,215 <br /> Telephone(800) 511-9300 • Fax(8881445-8786 <br /> An LImployee-Owned Company <br />
The URL can be used to link to this page
Your browser does not support the video tag.