Laserfiche WebLink
l , • ` Sequoia 680 Che peakc Drive Redwood City,CA 9400 (415) 364-9600 FAX(415) 364-9233 <br /> 404 N.Wiget lane Walnut Creek,CA 94598 - (510) 988.9600 FAX(510)988-96404 N.Wiget lane Walnut Creek,CA 94598 - (510) 988.9600 FAX(510)988-9673 <br /> Analytical 819 Striker Avenue,Suite 8 Satnnnento,CA 95834 (916) 921-9600 FAX(916)921-0100 <br /> Mr. Tony Martin <br /> Kleinfelder <br /> 2825 East Myrtle Street <br /> Stockton, CA 95205 <br /> Subject: Method Blank Contamination from Acetone. <br /> This laboratory narrative is for the following projects that were analyzed for Semi- <br /> Volatile Organics by EPA Method 8270+ Open Scan: <br /> Sequoia I.D. Client Project I.D. Date Received/ COC# <br /> 1. 7010413-0442 20-397801.WR4 Spreckels 1/14/97 241, 242 <br /> 2. 7010397-0400 20-397801.WR4 Spreckels 1/14/97 606 <br /> 3. 6121287-1302 20-397801.WR6 Spreckels 12/31/96 296 <br /> 4. 7010363-0375 20-397801.WR4 Spreckels 1/13/97 605 <br /> 5. 6121077-1079 20-397801.WR4 12/23/96 193 <br /> 6. 6121065-1073 20-397801.WR5 12/23/96 186 <br /> 7. 7010455-0459 20-397801.WR6 Spreckels 12/27,31/96 295, 296 <br /> 8. 7011286-1301 20-3978-01-W13 12/31/96 11949 <br /> Sequoia Analytical in Sacramento received samples from Kleinfelder during the time period <br /> of December 1996 through January 1997 for EPA 8270 + Open Scan. On these projects Sequoia <br /> Analytical reported several hits on the Open Scans for the above projects. Sequoia Analytical <br /> was requested to review the Open Scan results for the initial batches of samples submitted in <br /> December to verify if the reported compounds were actually in the samples. Because the <br /> reported compounds were not detected in the method blank for these batches, it was thought that <br /> the possibility of lab contamination was slight if at all. <br /> Towards the end of this project, it was noted that similar compounds were seen in the method <br /> blank as in the samples. Sequoia Analytical then pulled all of the EPA 8270 raw data for the <br /> entire project and it was discovered that through out the project there had been a trend of 1 to 4 <br /> compounds that continually showed up in the Open Scans at about the same concentrations in <br /> the samples and in the method blanks. After further investigation of the different solvents and <br /> different lots it was determined that a new lot of Acetone being used during the extraction <br /> process was contaminated with similar compounds, at similar concentrations, as reported on the <br /> following pages. <br /> It is Sequoia Analytical's policy as well as an industry standard to not subtract method blank <br /> concentrations from sample concentrations. However, it is believed that the compounds which <br /> were consistently detected in the method blanks and the samples were present due to the <br /> contaminated lot of Acetone used in the extraction process. A summary of the compounds are as <br /> follows. <br />