Laserfiche WebLink
KLEINFELDER <br /> A-2.6 Soil Sample Selection for L thoratory Analysis <br /> The selection of soil samples for laboratory analysis is based upon: 1) the project objectives and <br /> requirements, 2) qualitative Feld screening performed in the field using the organic vapor <br /> detector, and 3) field observations such as lithology, odor, discoloration, or high moisture <br /> content. Generally, samples are submitted from the bottom of the boring and from soil horizons <br /> with significant potential for contamination as indicated by the organic vapor detector, <br /> observations, and site history. Samples may be collected from regular intervals when <br /> information on concentrations versus depth is desired. Samples that are not selected for <br /> laboratory analysis are held in sample control for possible future reference. When these samples <br /> are no longer needed, they are returned to the site and are combined with the soil cuttings <br /> generated during their collection. <br /> A-2.7 Soil Boring Closure and Soilutting Disposal <br /> Soil borings are closed immediately after the collection and logging of soil samples. Closure is <br /> accomplished by grouting the boring with a cement/bentonite slurry or as otherwise required. <br /> Drill cuttings will be placed in 55-gallon drums or wrapped in plastic and left on site for disposal <br /> by the site owner. If requested, Kleinfelder can coordinate disposal of soil and water with <br /> contractors after chemical analysis results are available. <br /> 20-3978-0I.W 35/201 715 5 1 <br /> Copyright 1997.Kleinlelder. Inc. Page No.A-3 <br /> September 26, 1997 <br />