My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SPRECKELS
>
18800
>
2900 - Site Mitigation Program
>
PR0506460
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2020 1:07:30 PM
Creation date
5/14/2020 12:32:12 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0506460
PE
2950
FACILITY_ID
FA0007440
FACILITY_NAME
ATHERTON KIRK/SPRECKELS
STREET_NUMBER
18800
STREET_NAME
SPRECKELS
STREET_TYPE
RD
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
18800 SPRECKELS RD
P_LOCATION
04
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
KLEINFELDER <br /> File No. 20-3978-01.W 10 <br /> July 26, 1997 <br /> 21)A railroad spur(s) has been located on site since construction of the factory. Various <br /> herbicides or waste oil may have been used for weed control along the railroad tracks. <br /> Hazardous substances may have been transported on site via railcars. Creosote or <br /> pentachlorophenol may have been used to treat the railroad ties in the railbed. <br /> Locomotive maintenance was conducted on site wherever necessary. PCBs, oils, and <br /> solvents may be associated with said maintenance. <br /> According to Mr. Tucker, the rail spurs will remain on site to service future <br /> development. The rail spurs should be visually inspected for evidence of <br /> contamination. If obvious signs of contamination are discovered, sampling and <br /> analysis should be conducted. If the rail spurs are to be removed, then confirmation <br /> soil sampling should be immediately conducted after removal of the railbed to verify <br /> that no contamination is present. <br /> 22)Due to the long history of the former Spreckels Sugar Plant, and the lack of available <br /> documentation regarding potential environmental issues at the site, additional <br /> environmental concerns (such as undiscovered landfills, soil staining, previously <br /> unknown USTs etc.) which were not revealed during this assessment may be <br /> discovered during development. Additionally, Kleinfelder is continuing attempts to <br /> locate and interview former Spreckels employees. If additional environmental issues <br /> are discovered during development of the site, or are revealed by interviews with <br /> former Spreckels employees, Kleinfelder should be contacted for additional <br /> consultation. <br /> 23)Several issues of potential geotechnical significance were identified during this <br /> assessment. Evaluation of geotechnical issues is beyond the scope of an ESA. The <br /> potential geotechnical issues include the impermeable pond bottoms in the southeast <br /> 33 acres of the site, the practice of spreading tare dirt and waste organic matter over <br /> the feed lots and fields, and the presence of a concrete slab (reported by Mr. Tucker) <br /> buried approximately 8 feet below the factory. These issues should be evaluated by a <br /> geotechnical engineer prior to development of the site. <br /> 24)The California Division of Oil and Gas should be consulted in writing prior to <br /> development in the area of the former oil test well. <br /> 25)Soil samples should be collected in the vicinity of the cooling towers and analyzed for <br /> the presence of hexavalent chromium. <br /> 20-3978-01.W1012017L155 Page 14 of 50 Copyright 1997,Kleinfelder,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.