Laserfiche WebLink
F1leNo. 20-3978-0LW15 KLEINFELDER <br /> January 6, 1997 <br /> B-2.3 Collection of Soil Samples <br /> Soil samples are collected approximately every 5 to 10 feet for field screening and <br /> logging. Samples are collected by advancing the boring to a point immediately above the <br /> desired sampling depth and then driving (vertical borings) or pushing (slant borings) a 2- <br /> inch diameter Modified California Split-Spoon Sampler, lined with three 6-inch long <br /> brass tubes, into the undisturbed soil. The sampler is then removed from the bottom of <br /> the boring. The ends of the bottom (third) tube are covered with Teflon and sealed with <br /> tight fitting plastic caps. <br /> Each sample is individually labeled. The label includes Kleinfelder's name,job number, <br /> the date and time the sample was collected, the employee number of the individual who <br /> performed the sampling, and a unique five-digit sample identification number. <br /> B-2.4 Hydropunch II'm Groundwater Sampling <br /> Hydropunch IIT^" is a method to collect representative groundwater samples from <br /> boreholes without the need to install monitoring wells. This method is usually used as an <br /> exploration tool for screening groundwater quality and reducing the number of wells <br /> needed at a site. <br /> A boring is drilled to the desired sampling depth, usually to the top of the groundwater <br /> surface, using hollow stem augers. The Hydropunch IIT"^ system, consisting of a steel <br /> drive point attached to a stainless steel barrel with an internal PVC slotted screen, is <br /> driven 2 to 3 feet past the bottom of the boring into the uppermost water bearing zone. <br /> The barrel is connected to the surface using clean, 2-inch diameter hollow steel rods. The <br /> barrel is then pulled back 1 to 2 feet exposing the internal PVC screen to the soil. <br /> Groundwater then enters the barrel through the screen under hydrostatic pressure and is <br /> brought to the surface with a clean, Teflon or stainless steel bailer. The samples are <br /> immediately labeled and placed in an iced sample container. <br /> Equipment used for Hydropunch IIT"" sampling is decontaminated prior to use at each <br /> sampling location by steam cleaning, or by scrubbing in a trisodium phosphate or non- <br /> phosphate detergent wash followed by a distilled water rinse. <br /> 203978-Ol.W15/207PE009 PageB-2January 6, 1997 <br /> Copyright 1997, Kleinfelder, Inc. <br />