Laserfiche WebLink
SS WYE <br /> INV 27"83 6"NW <br /> INV 27.83 6"SE ` fi\ " <br /> INV 27.83 61W <br /> ._... ..._..,,,• TRENCH EXCAVATION SAFETY PROTECTION. <br /> LEACH LINE ~' ' CONTRACTOR AND!OR CONTRACTOR'S INDEPENDENTLY RETAINED EMPLOYEE OR STRUCTURAL <br /> SEPTIC INLET <br /> RIM 32,51 FG 29.77 74 DESIGN 1 GEOTECHNICAL 1 SAFETY 1 EQUIPMENT CONSULTANT,IF ANY,SHALL REVIEW THESE <br /> 'NW <br /> ' INV 27A4 4"W PLANS AND ANY AVAILABLE GEOTECHNICAL INFORMATION AND THE ANTICIPATED INSTALLATION <br /> INV 27.816 - <br /> INV 27.44 4"SE \ - - SITES WITHIN THE PROJECT WORK AREA IN ORDER TO IMPLEMENT CONTRACTORS TRENCH <br /> EXCAVATION SAFETY PROTECTION SYSTEMS,PROGRAMS,AND!OR PROCEDURES FOR THE <br /> SEPTIC O'0TLET. <br /> 7 / PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS.THE CONTRACTOR'S IMPLEMENTATION OF <br /> Tf / RIM 30.47 - < ry .- _ --- -:: 25 S I E G F R I E D <br /> �-� THESE SYSTEMS,PROGRAMS AND 1 OR PROCEDURES SHALL PROVIDE FOR ADEQUATE TRENCH <br /> fi INV 2T64 4"SE -� _..-_. --- _ '` EXCAVATION SAFETY PROTECTION THAT COMPLY WITH AS A MINIMUM OSHA STANDARDS FOR <br /> TRENCH EXCAVATIONS,SPECIFICALLY,CONTRACTOR AND 1 OR CONTRACTOR'S INDEPENDENTLY <br /> 3 oL'Z _ _ -_ RETAINED EMPLOYEE OR SAFETY CONSULTANT SHALL IMPLEMENT A TRENCH SAFETY PROGRAM <br /> - \ 9 , .- ..r <br /> - 24 - - 3244 Brookside Road <br /> DIST.BOX IN ACCORDANCE WITH OSHA STANDARDS GOVERNING THE PRESENCE AND ACTIVITIES OF <br /> ---.. - - -_..._ Suite 100 <br /> RIM 29.74 __�_____ _. INDIVIDUALS WORKING IN AND AROUND TRENCH EXCAVATION. <br /> Stockton,California 9b219 <br /> - <br /> ........_ <br /> s 09- 2LEACH LINE <br /> FG 22.77 7 � F209-940214 <br /> _ <br /> �( UTILITY CONSTRUCTION NOTES: <br /> ~ f �f r INV 4SE N <br /> \` ---�__.____---_- --� --- www.siegfriedeng.com <br /> INV 27"44 4 E r <br /> + fig\ �� TYP <br /> �.... <br /> 1 I 1. CITY OF STOCKTON STANDARD ■ <br /> � ��--�--- � ALL MATERIALS AND CONSTRUCTION PROCEDURES WITHIN THE SCOPE OF THIS <br /> SEEPAGE PIT 3 I <br /> " ' _.� _-_.." CONTRACT SHALL CONFORM TO ALL APPLICABLECIVIL <br /> \ / \ INV 27.37 4 NW \ SPECIFICATIONS(LATEST EDITION)AND THE CALIFORNIA DEPARTMENT OF E N G I N E E R I N G <br /> 5 SEEPAGE PIT 2 a TRANSPORTATION STANDARD SPECIFICATIONS(LATEST EDITION). <br /> STRCTURAL <br /> TYP INV 27,394"NW 21 ■ ENGINEERING <br /> 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ACQUIRING ALL PERMITS,TESTS, <br /> SEEPAGE PIT 1 TP APPROVALS AND ACCEPTANCES REQUIRED TO COMPLETE CONSTRUCTION OF THIS <br /> INV 27.37 4"NY,f NPROJECT. ■ LAND <br /> o <br /> SURVEYING <br /> 3. CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF UNDERGROUND UTILITIES AND <br /> 13 fi� ' 6 6 1---. - 6 DRAINAGE SYSTEMS WHETHER SHOWN ON PLANS OR NOT. ■ LANDSCAPE <br /> f. a_ ► _ _ _ <br /> 1 \ i - ___._ ..... 1$ i ARCHITECTURE <br /> Xx <br /> 4. ALL UTILITIES SHALL BE INSTALLED PRIOR TO PAVEMENT CONSTRUCTION, <br /> 5. DUE TO FEDERAL REGULATIONS TITLE 49,PART 192,181,CITY PUBLIC SERVICE MUST <br /> 1 �.� �j! `f LEACH FIELD DETAIL (:j��AT� INE CONNECTION DETAIL MAINTAIN ACCESS TO GAS VALVES AT ALL TIMES.THE CONTRACTOR MUST PROTECT AND <br /> + 1 ` // ? �./ 1"= 1Q' 1"= 10' WORK AROUND ANY GAS VALVES THAT ARE IN THE PROJECT AREA. <br /> ~ / 6. ALL SPOIL AND OTHER UNSUITABLE MATERIAL FROM THIS WORK SHALL BE REMOVED <br /> FROM THE SITE BY THE CONTRACTOR,AT HIS EXPENSE. <br /> KEY NOTES: REVISIONS <br /> No. Date Description <br /> INSTALL 44 X27"ARCHED REINFORCED CONCRETE PIPE CULVERT. 10 FUTURE LEACH FIELD AND SEEPAGE PITS. EXISTING UTILITIES: <br /> + % / \ % % ❑ MATCH FLOWLINE OF CULVERT TO BE REMOVED.SEE DETAIL 1 ON ❑ 11\ 10103118 PLAN CHECK 1 <br /> SHEET C4.2. <br /> INSTALL GATE VALVE PER CITY OF STOCKTON STANDARDS 1. EXISTING UTILITY DATA SHOWN ON THIS LAYOUT WAS OBTAINED FROM A SURVEY OF THE <br /> 2 INSTALL SANITARY SEWER CLEANOUT PER DETAIL 12 ON SHEET <br /> C7.0. INSTALL FIRE HYDRANT PER CITY OF STOCKTON STANDARD VISIBLE FEATURES AT THE SITE AND PUBLIC RECORD MAPS OBTAINED FORM UTILITY <br /> COMPANIES. <br /> aINSTALL 1,500 GAL SEPTIC TANK PER SAN JOAQUIN COUNTY DRAWING NO.W-13. <br /> ENVIRONMENTAL HEALTH DEPARTMENT STANDARDS. INSTALL RETENTION BASIN PER SAN JOAQUIN COUNTY 2. THE CONTRACTOR SHALL NOTIFY ALL UTILITY COMPANIES WITHIN 48 HOURS PRIOR OF <br /> + ++ Fr 4 INSTALL LEACH FIELD PER SAN JOAQUIN COUNTY ENVIRONMENTAL ,3 STANDARDS. CONSTRUCTION TO LOCATE AND TAG THEIR UNDERGROUND FACILITIES PRIOR TO <br /> + / , ` \ , / ❑ <br /> HEALTH STANDARDS. 14 <br /> � STUB FOR IRRIGATION LANE AND APPURTENANCES.SEE EXCAVATION. <br /> INSTALL 48"O SEEPAGE PIT PER SAN JOAQUIN COUNT ❑ LANDSCAPE DRAWINGS FOR CONTINUATION. 3• THE CONTRACTOR NEEDS TO ALLOW FOR THE POSSIBILITY OF UNDETECTED <br /> + / + '� 1 } jam, ❑ ENVIRONMENTAL HEALTH DEPARTMENT STANDARDS. 15 NS S :gp - UNDERGROUND UTILITIES.ALSO,THE CONTRACTOR MUST ALLOW FOR CHANGES DUE TO <br /> ❑ <br /> INSTALL SEDIMENT FOREBAY. <br /> UTILITIES BEING IN LOCATIONS DIFFERENT FROM THOSE SHOWN ON THE UTILITY RECORD <br /> + \ ` - ! / ❑ CONNECT TO EXISTING WATER PER CALWATER STANDARDS. ELECTRICAL AND COMMUNICATIONS LINES SHOWN FOR DRAWINGS.THE CONTRACTOR IS RESPONSIBLE FOR LOCATING AND EXPOSING CONFLICTS <br /> PRIOR TO CONSTRUCTION. <br /> 19 <br /> + � � �\ �f f, � °; ❑T INSTALL GATE VALVE PER CALWATER STANDARDS. 16 REFERENCE ONLY.REFER TO ELECTRICAL PLANS. <br /> 17 RELOCATE TRAFFIC SIGNAL BOX AND CONCRETE PAD FROM 4. THE LOCATIONS AND DEPTHS OF EXISTING UTILITIES SHOWN ON THESE PLANS ARE <br /> INSTALL 10"DOUBLE DETECTOR CHECK ASSEMBLY PER CALWATER <br /> LOCATION SHOWN ON SHEET C2.0. APPROXIMATE ONLY.ACTUAL LOCATIONS AND DEPTHS OF UTILITIES MUST BE VERIFIED BY <br /> + r� ❑ <br /> STANDARDS. THE CONTRACTOR PRIOR TO CONSTRUCTION, IT SHALL BE THE CONTRACTOR'S <br /> 1B INSTALL WATER SERVICE LINE FOR FUEL ISLAND. RESPONSIBILITY TO LOCATE UTILITY SERVICE LINES AS REQUIRED FOR CONSTRUCTION PROJECT <br /> 9 INSTALL 2"BACKFLOW PREVENTER PER CALWATER STANDARDS. AND NOTIFY THE ENGINEER OF ANY CONFLICTS IMMEDIATELY.ANY DAMAGE BY THE <br /> + fi f 19 INSTALL WATER SERVICE LINE FOR HOSE BIBS. CONTRACTOR TO EXISTING UTILITIES,WHETHER SHOWN ON THE PLANS OR NOT,SHALL BE <br /> THE CONTRACTORS RESPONSIBILITY TO REPAIR,AT HIS EXPENSE. <br /> INSTALL GOUBLE ME ER PANEL. <br /> + ++ 12 <br /> ALL WATER FACILITIES IN FRONT OF PROPERTY LINE TO BE <br /> 1 1 26 '^ SS WYE ` / X x ❑ INSTALLED BY CALWATER. <br /> + INV 29.09 6"SW ® \ x / ' <br /> + ifi \ +► 2 \\ INV 29.09 6"SE INV 29.09 6"NW PROVIDE WATER STUB FOR BUILDING. <br /> \ a ti \` fi� / /y / <br /> 22 <br /> 1 TP / \ •' f FOR TRAFFIC SIGNAL MODIFICATIONS,REFER TO SHEETS E-1 <br /> THROUGH E-3- McFadden <br /> 1 p-Q �O / / SS STUB 2 \\ 18 fi` j 24 INSTALL 2"IRRIGATION BACKFLOW ASSEMBLY.SEE IRRIGATION Development <br /> + INV 29.13 6"NE \ ❑ PLAN FOR DETAILS. <br /> + G ++ 6"5S \\ 37 LF •'v \ 25 INSTALL WATER METER PER CALWATER STANDARDS. <br /> 1 \ BLF @ S-0.0050 a \ ❑ <br /> 1 1 <br /> ++ \ \\ +1 0• / \ FOR TRUCK WASH AREA, REFER TO SHEET C5.1. <br /> SEWER STUB TO TRUCK WASH AREA,REFER TO SHEET C5.1 FOR <br /> \ \ 1 • � �' \ �` 27 INVERTS. <br /> u.lSS WYE <br /> \ \ INV 28.60 fi"SWINV o <br /> 1 \ 1 860 y ..e. .e.p. � �.� 3817 & 3855 <br /> 2 INV 2 <br /> ►� \ \, ,+ r7LF 28.60 VE � �` � _ E. Farmington Rd <br /> \ • SS STUB 1 @ S_0 a050 ' <br /> Stockton, CA 95215 <br /> 12 fi <br /> a <br /> \ •, INV 28.65 6"NE \ B" <br /> 6'SS <br /> 10LF @ S=0.005077LF@ 50050 2eRoVESsroN <br /> 0-0 �y � SS WYE6. <br /> + +� C INV 27.83 6"NW • 4 m <br /> \ / INV 27.$3 fi"SE • T YP ] ,( /- _ - <br /> NO <br /> \ INV 27.83 6"W y` ,tel / /�;� = �� 972 <br /> 9 <br /> E 12/31/19 <br /> 20 1© <br /> TYP i`�y i , Y ......"...... s'Tgrf 01V1\- <br /> TY �P <br /> C - ..._,.. - .. 1�< DATE SIGHED:OF CAO <br /> 10130118 <br /> f i <br /> 5L - <br /> _ � - <br /> --- <br /> 2"W 2"W TY <br /> �110LF11 LF rrur <br /> SHEET TITLE <br /> r <br /> A3� 23 <br /> - "� _ UTILITY PLAN <br /> ---- 23 . <br /> 2"V - } <br /> a '� �- V <br /> „W 23 <br /> 10"FW <br /> 1 -- )... ._._. 38 LF _ <br /> E _.....,,.... - <br /> W 37 LF <br /> i --- - <br /> �Q 4�J <br /> _ - -- --- 18V 8 LF <br /> ® <br /> - <br /> } _... .. <br /> y _ � nn <br /> �r <br /> Proj Mgr AJL <br /> Q. <br /> 21C:_- G�ON Drawn b <br /> € 2 1 <br /> V Q Y GW <br /> \ TYP F�� __ <br /> a - 1 0' 15' 30' 60' Data Oct. 30 2018 <br /> G ..,: :_- f,....... <br /> � O� __ aH -_ OH -�f--- SCALE: 1 =30' Job No. 17026 <br /> V Know whafs below. \ - _ " <br /> N 1 f'•11-1 _ <br /> Call before you dig. <br /> SHEET: <br /> V <br /> a <br /> C5,0 <br />