Laserfiche WebLink
01/30/2007 13:03 2095991303 FR PAPER RIPON MILL PAGE 05/09 <br /> North Coast Laboratories. Ltd. Dace: 30-Noy-2006 • <br /> CLIENT: 1 L Analytical Scrviecs '-- — <br /> : r 1.1194 <br /> T-A OrCASE NARRA'T'IVE <br /> r.ah order: 061 tse2 <br /> MethylEthyll<etone: <br /> The laboratory control sample/laboratory control sample duplicate(LCS/LCSD)recoveries were above <br /> the upper acceptance limit for tnethylethylketone. These rcoovcries indicate that the sample results may <br /> be erroneously high. There were no detectable levels of the analyte in the Sample; therefore, the data <br /> were accepted. <br /> The saluple was rcpurled as not detected(ND)with a dilution due to matrix interference. <br /> Acetone: <br /> The LCS/LCSD recoveries were below the lower acceptance limit for acetone. The response of the <br /> reporting limit standard was such that the analyte would have been detected even with the low <br /> recoveries; therefore, the data were accepted. <br /> The sample was reported as not detected ('ND) with a dilution due to matrix interference. <br /> • <br /> 1 <br /> NORTH COAST LABORATORIES <br /> 5620 Weat End koad - AICMA,CA(crnia 955279202 . 707 9224649 - FAX 707.0226831 <br /> ��Aiwu.rMnwlFr <br /> 9E/Ee 29vd SSVI ISV00 H18ON TE89ZZ9106 SZ 5T 9801/T0/ZT <br />