My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
3227
>
2200 - Hazardous Waste Program
>
PR0513928
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2020 11:12:54 AM
Creation date
5/15/2020 11:02:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0513928
PE
2220
FACILITY_ID
FA0004046
FACILITY_NAME
GTS TRANSMISSIONS
STREET_NUMBER
3227
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
15708116
CURRENT_STATUS
02
SITE_LOCATION
3227 E MAIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
KM KELLYWOOff <br /> L <br /> PAINTS ' 140 Exterior Flat Paint <br /> MIXING Mix well before use . Purchase enough paint to complete your project at the same time . If additional paint is <br /> needed , retain some of the original material and intermix the paint before application or touch up . <br /> THINNING Apply at can consistency. If thinning is necessary to maintain workability, do not exceed one - half pint of <br /> water per gallon . <br /> DRYING Dry times are based on standard conditions of 75 ° F with a relative humidity of 50 % . Lower temperatures or <br /> higher humidity may extend drying times . Higher temperatures may speed drying time . <br /> Provide adequate ventilation and air movement during and after painting . <br /> TEMPERATURE Do not apply when material , air, and/or surface temperature is outside of the recommendations on <br /> page 1 . Store at room temperature and protect from freezing . <br /> COVERAGE May vary depending on method of application , porosity and texture of the surface . <br /> NEW SURFACES Prime surfaces following primer recommendations on Page 1 and 2 . <br /> Two finish coats will provide a more even color and sheen . It will also help with touch - up and durability. <br /> Backroll while spraying to ensure an even coat . Backrolling the prime coat will fill in porous surfaces . Backrolling the <br /> topcoat will reduce pinholes , create uniform sheen , and make for easier touch - up . <br /> Avoid lap marks by maintaining a wet edge at all times . Re - wet your applicator before it starts to run dry; any light <br /> spots , when dried , may appear different than heavy spots in both color and sheen . An even coat is your goal . <br /> Lay the paint on and leave it alone . Be sure to give paint an opportunity to flow and level after application . <br /> This product is not intended for use on floors . <br /> PREVIOUSLY PAINTED SURFACES Glossy surfaces should be completely dulled prior to painting . <br /> Spot prime bare and patched areas or prime entire surface with a suitable Kelly- Moore product . <br /> Vhen making a significant color change, a primer is recommended to aid hide and appearance of the finish coating . <br /> ollow application instructions for ` new surfaces ' listed above . <br /> STAIN BLOCKING When painting over stains or tannins , an appropriate primer is recommended before top coating . <br /> For heavy stains , a second coat of primer may be required . 24 hours are required between all coats . <br /> FIBER CEMENT BOARD Follow primer recommendations on Page 1 . A minimum of two finish coats at 4 - 6 wet mils <br /> are required over factory prime for sheen uniformity and touch up . Backroll spray applied topcoats . <br /> CAULKING When filling voids, prime the surface then apply paintable patching , acrylic caulking , or siliconized acrylic <br /> caulking to the manufacturer 's recommendations . Allow the caulking to fully dry, then apply the finish paint . <br /> When sealing voids or joints with expected movement , prime and paint the surface . Allow the paint to fully dry, then <br /> apply acrylic or siliconized acrylic caulking . Clear or colored caulking is a good choice for this type of application . <br /> Painting over caulking were substrate movement is present may cause cracking of the finish coating . <br /> CONTAINERS AND TOOLS Transfer material into a clean container before use . Use new or thoroughly cleaned <br /> tools . To avoid contamination , do not re - dip applicators or add used material into containers being used for storage . <br /> STORAGE Store material in a clean , tightly sealed container free of rollers , brushes , or other outside materials . <br /> TESTING Prior to full application , apply a test patch to ensure the preparation and coating system are appropriate <br /> for the project . If test patch results do not meet the needs of the project , contact a Kelly- Moore representative for <br /> recommendations . <br /> CURE Architectural coatings require up to 30 days after final application for full cure . Cure times vary depending <br /> on environmental conditions and air circulation . Full performance characteristics are achieved when coating has fully <br /> cured . <br /> CLEANING Wait at least two weeks after application before attempting to clean or maintain the surface . Use a <br /> new soft cotton cloth or sponge with clean water to wipe the surface . If the surface has heavy dirt or stains , a mild <br /> detergent may be added to the water for cleaning . Clean tools with warm soapy water. <br /> www. kellymoore.com Rev, 09/18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.