Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM (Page 2 of 6) <br /> V. TANK SECONDARY CONTAINMENT INFORMATION <br /> Manufacturer Identify Tank ID from Section III for each Manufacturer <br /> Owens Corning A El I B x❑ I C 0 I D ❑ <br /> A ❑ I B ❑ I C ❑ I D ❑ <br /> Test Method Used : ❑ Manufacturer Guidelines (Specify): <br /> ❑ Industry Code or Engineering Standard (Specify) : <br /> ❑ Engineered Method (Specify): <br /> # of Attached Pages <br /> Attach the testing procedures and all documentation required to determine the results. <br /> Tank Containment Testing Training and Certifications (List applicable certifications) Expiration Date <br /> VI . COMMENTS <br /> Provide any additional comments here. <br /> Tank A is a 12K Double Wall Fiberglass , with a Brine Filled Tank Secondary Containment, and is exempt from periodic <br /> testing . Tank A is designated for, 11 , 627 Gallons Premium 91 Octane Gasoline . <br /> Tank B is a 12K Double Wall Fiberglass , with a Brine Filled Tank Secondary Containment, and is exempt from periodic <br /> testing . Tank B is designated for, 11 , 627 Gallons Regular 87 Octane Gasoline . <br /> Tank C is a Double Wall Fiberglass , with a Brine Filled Tank Secondary Containment, and is exempt from periodic testing . <br /> Tank C is designated for 11 , 627 Gallons Diesel <br /> VII . PRODUCT PIPING CONTAINMENT TESTING INFORMATION <br /> Manufacturer Identify Tank ID from Section III for each Manufacturer <br /> Smith FRP AM I B x❑ CM D ❑ <br /> A ❑ I B ❑ I C ❑ I D ❑ <br /> Test Method Used : ❑x Manufacturer Guidelines (Specify) : * Bravo Systems Coated Steel UDC's . 3 Psi- 1 Hour <br /> ❑ Industry Code or Engineering Standard (Specify): <br /> ❑ Engineered Method (Specify): <br /> # of Attached Pages <br /> Attach the testing procedures and all documentation required to determine the results. 2 <br /> Product Piping Containment Testing Training and Certifications (List applicable certifications) Expiration Date <br /> ICC Service Technician #5246802 - UT 3/21 /2021 <br /> Underground Storage Tank Tester License #90- 1120 12/31 /2022 <br /> Interstitial Communication Verification Method Used : <br /> NA-Section III -Sealed System at Termination end of Piping Runs at Bravo System Coated Steel UDC's . <br /> VIII . COMMENTS <br /> Provide any additional comments here. <br /> *Section VII -See Test Procedure Attachment for Product Piping Test Pressure , Time and Protocol , for Fiberglass Piping <br /> Systems that terminate at Bravo System Coated Steel UDC's . <br /> ID = Identification <br />