Laserfiche WebLink
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for GSG GAS & MART as of May06 , 2020 . <br /> Open violations from June 24, 2019 inspection <br /> Violation #206 - Failure to comply with UST operating permit conditions . <br /> The designated operator' s inspection reports and the manager onsite indicated that UDC 3/4 was impacted by a <br /> truck in September of 2018 and they are waiting to hear from the contractor to replace the dispenser . A repair <br /> permit application was not submitted to the EHD for this service. All repairs must have a permit submitted to and <br /> approved by the EHD prior to beginning work . Immediately, have a properly licensed , trained and certified contractor <br /> repair or replace the damaged component under permit and inspection of EHD . <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Violation #301 - UST system is not operated to prevent unauthorized release, including spills and overfills . <br /> The designated operator' s inspection reports and the manager onsite indicated that UDC 3/4 was impacted by a <br /> truck in September of 2018 and they are waiting to hear from the contractor to replace the dispenser. Secondary <br /> containment testing has not been conducted to verify the integrity of the piping . The underground storage tank <br /> system shall be operated to prevent unauthorized releases . Immediately verify the integrity of the underground <br /> storage system . <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Violation #320 - Failure to comply with the installation , inspection , or record keeping of the overfill <br /> prevention . <br /> Overfill prevention testing has not been conducted . According to the service technician onsite this testing was <br /> scheduled to be conducted today but it was canceled because they were having trouble with removing the drop <br /> tube . This testing was required to be conducted by October 13 , 2018 . Immediately schedule this testing and provide <br /> 48 hours notification to the EHD . Ensure all future testing is conducted within required time frames . <br /> ❑ This violation was corrected ❑ This violation will be corrected by ( date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Page 1 of 1 <br />