Laserfiche WebLink
pU'N 'Z SAN J OAQU I N Environmental Health Department <br /> Q ._ , _ <br /> " ,, ` ' ` COUNTY Kasey Foley , REHS , Interim Director <br /> ePROGRAM COORDINATORS <br /> . k1Foa� Greatness grows here . Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Muniappa Naidu , REHS <br /> Michael Kith , REHS <br /> Melissa Nissim , REHS <br /> March 5 , 2020 <br /> Mark Vendeiro <br /> MVP Petroleum Engineering , Inc . <br /> PO Box 281 <br /> Folsom , CA 95763 <br /> Re : Country Club Mobil Circle K SR0081719 <br /> 2575 Country Club Blvd . , Stockton , CA 95204 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a 1 hour plan check service request to replace penetrations in the 91 STP sump <br /> (without piping disconnection ) and install a test port in the 91 fill sump on the underground storage <br /> tank ( UST) system at the above noted address . The plan check service request has been approved <br /> with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust c6 slgov . org for the following repairs and testing ( a 48 - hour <br /> notice is required ) . Please be aware that inspections for emergency work must be scheduled <br /> within five days of plan check service request approval . <br /> a . Integrity testing of 91 fill and STP sumps per the manufacturer' s instructions <br /> b . Refilling sump ( s ) with proper manufacturer- issued brine and in accordance with <br /> manufacturer procedures . <br /> c . Verification of leak monitoring communication for all installed vacuum , pressure , or <br /> hydrostatic (VPH ) components in the 91 fill and STP sumps . <br /> 4 . If concrete will be broken near the piping , sumps , or tanks , a secondary containment test must <br /> be performed on the affected components once concrete is poured in accordance with the <br /> manufacturer' s guidelines , and test results submitted to the EHD within 30 days of testing . <br /> 5 . Secondary containment testing for the 91 fill sump and 91 STP sump is required six months <br /> after installation . Provide 48 hours notification to the EHD when this test is scheduled . <br /> 6 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be issued <br /> to the installation company) , or a Tank Tester' s license issued to the individual by the State <br /> Water Board , and <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 T 209 468 -3420 F 209 464 -0138 1 www . sjgov . org/ehd <br />