Laserfiche WebLink
SAN 10 A Q U I N Environmental Health Department <br /> ICOUNTY Jasjit Kang , REHS , Director <br /> FoaP" Greatness grows here . Muniappa Naidu , REHS , Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Michael Kith , REHS <br /> Melissa Nissim , REHS <br /> November 24 , 2020 <br /> Mark Vendeiro <br /> MVP Petroleum Engineering , Inc . <br /> PO Box 281 <br /> Folsom , CA 95763 <br /> Re : Country Club Mobil Circle K SR0080273 <br /> 2575 Country Club Blvd . , Stockton , CA 95204 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a permit to do the following on the underground storage tank ( UST) system at the above <br /> noted address : <br /> • Replace the diesel penetration boot under dispenser 7/8 <br /> • Replace the test port in the 91 fill sump <br /> • Replace the electrical penetration in the 91 turbine sump <br /> • Replace the 87 penetration boots under dispensers 1 /2 and 7/8 <br /> • Replace the 91 penetration boots under dispensers 1 /2 and 5/6 <br /> • Replace 87 spill container <br /> • Repair communication under dispenser 3/4 <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust (Dsigov . orq to arrange the following appointments (a 48 - hour <br /> notice is required for inspection appointments) . <br /> a . Verification of brine type and witnessing of brine addition <br /> b . Verification of leak monitoring and communication for vacuum , pressure , or hydrostatic <br /> (VPH ) components . <br /> c . Visual inspection of sumps and newly installed penetrations . <br /> d . Spill bucket test : Verify minimum 5 -gallon capacity and pass a one hour hydrostatic test <br /> ( or equivalent) . Proper drainage method must be verified . <br /> 4 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be <br /> issued to the installation company) , or a Tank Tester' s license issued to the individual by <br /> the State Water Board <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 T 209 468-3420 F 209 464 -0138 1 www . sjgov . org/ehd <br />