My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
1901
>
2300 - Underground Storage Tank Program
>
PR0231092
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2021 9:05:26 AM
Creation date
5/15/2020 4:36:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231092
PE
2361
FACILITY_ID
FA0001946
FACILITY_NAME
El Dorado Food Mart
STREET_NUMBER
1901
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16508019
CURRENT_STATUS
01
SITE_LOCATION
1901 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for EI Dorado Food Mart as of May 01 , 2020 . <br /> Open violations from August 29 , 2019 inspection <br /> Violation #113 - Failure to submit " Monitoring System Certification Form " within 30 days of completion of <br /> the test. <br /> A monitoring system certification , and leak detector testing were performed on 8/14/18 . A test report has not been <br /> submitted to the EHD or the California Environmental Reporting System (CERS ) . A copy of the test report must be <br /> submitted within 30 days of the test . Immediately provide this report to the EHD . <br /> ❑ This violation was corrected ❑ This violation will be corrected by ( date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Violation #313 - Failure to construct, operate , and maintain primary containment as product-tight. <br /> Fuel drips were observed on both fuel filters under dispenser 1 /2 . All primary containment for the UST system must <br /> be tight . Immediately have a properly licensed , trained , and certified contractor repair or replace the failed <br /> components , under permit and inspection of the EHD if necessary. <br /> ❑ This violation was corrected ❑ This violation will be corrected by ( date ) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Violation #319 - No spill bucket, failed to contain 5 gallons , no means to keep it empty , or failed to be <br /> tested . <br /> The 91 direct-bury spill container was noted as a a visual fail by the technician . Five gallon capacity of the 91 spill <br /> container was not tested due to the visual fail of the spill container by the technician . <br /> Annual spill container testing was last performed on 08/14/2018 and was due by 8/2019 . Testing has not been <br /> completed and is twenty three (23 ) days past due. This test is required once every 12 months. Immediately <br /> schedule this test and provide 48 hours notification to the EHD . Please be aware that all EHD staff time associated <br /> with a re inspection will be billed at our current hourly rate . <br /> ❑ This violation was corrected ❑ This violation will be corrected by ( date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Open violations from August 29 , 2019 inspection <br /> Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.