My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SANTA FE
>
23665
>
2900 - Site Mitigation Program
>
PR0526080
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/18/2020 8:53:51 AM
Creation date
5/18/2020 8:47:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0526080
PE
2965
FACILITY_ID
FA0017647
FACILITY_NAME
RIVERBANK WASTEWATER TREATMENT PLNT
STREET_NUMBER
23865
Direction
S
STREET_NAME
SANTA FE
STREET_TYPE
RD
City
RIVERBANK
Zip
95367
CURRENT_STATUS
01
SITE_LOCATION
23865 S SANTA FE RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CLEANUP AND ABATEMENT COR NO. 5-01-703 45 -9 - <br /> CITY <br /> 9 - <br /> CITY OF RIVERBANK WASTEWATER TREATMENT PLANT <br /> STANISLAUS COUNTY <br /> e. Direct precipitation and runoff contributions, using the 100-year annual total precipitation <br /> distributed monthly in accordance with historical mean monthly precipitation data. <br /> f. Evaporation (based on 80% of established pan evaporation rates for the vicinity). <br /> g. A continuous minimum freeboard of two feet in each pond. <br /> The water balance shall be supported by documentation showing the source of all climactic and <br /> operations data used. If the water balance shows that additional permanent storage is needed, the <br /> report shall include a preliminary(conceptual)design for the additional permanent storage <br /> facilities and a detailed schedule for engineering design, permitting and construction. <br /> 12. By 30 April 2002, the Discharger shall complete discing/ripping of the Winter 1, 2, 3, and 4 <br /> percolation ponds and shall submit a report providing the results of percolation tests for each pond <br /> to determine the actual percolation rate. The percolation rate shall be determined using the <br /> American Society for Testing and Materials (ASTM) Standard Test Method D 5093-90, D 3385- <br /> 94, or other method approved by the Executive Officer. A minimum of one site per pond shall be <br /> tested. <br /> 13. By 30 June 2002, the Discharger shall submit a second revised Water Balance and Disposal <br /> Capacity Calculation Report that calculates the current disposal capacity of the wastewater <br /> treatment plant. The calculation shall be performed in accordance with Paragraph 11 and shall <br /> include the long-term percolation values for the winter ponds based on testing conducted to <br /> comply with Paragraph 12 above. <br /> 14. By 30 August 2002, the Discharger shall complete permanent repair of the northern berm of the <br /> Winter Aeration Cell and Summer 1 Pond in accordance with the recommendations of a <br /> California-registered Geotechnical Engineer, and shall submit a technical report describing the <br /> actions taken to comply with this requirement. <br /> 15. By 30 August 2002, the Discharger shall submit a Report of Waste Discharge(RWD) to apply for <br /> revised Waste Discharge Requirements for the proposed permanent facility expansion. The RWD <br /> shall be accompanied by a draft CEQA document for the expansion and a proposed schedule for <br /> certification of that document. <br /> 16. By 30 October 2003, the Discharger shall certify that the plant expansion has been completed and <br /> that all capacity-related problems have been fully resolved. <br /> In addition to the above, the City of Riverbank shall comply with all applicable provisions of the <br /> California Water Code that are not specifically referred to in this Order. As required by the California <br /> Business and Professions Code Sections 6735, 7835, and 7835.1, all reports shall be prepared by, or <br /> under the supervision of, a registered professional engineer and signed by the registered professional. <br /> If, in the opinion of the Executive Officer, the City of Riverbank fails to comply with the provisions of <br /> this Order, the Executive Officer may refer this matter to the Attorney General for judicial enforcement <br /> or may issue a complaint for administrative civil liability. <br />
The URL can be used to link to this page
Your browser does not support the video tag.