RAYMOND GREER <br /> Page 2 <br /> (bgs) from the boring advanced between the two former underground storage <br /> tanks (UST) on March 7, 1997 were 1,400 parts per million (ppm) Total <br /> Petroleum Hydrocarbon as Gasoline (TPH-G), 23 ppm Benzene (B), 200 ppm <br /> Toluene (T), 53 ppm Ethyl-Benzene (E), and 410 ppm Xylenes (X). Petroleum <br /> contamination was present in all soil samples collected at ten feet intervals <br /> between 20 feet bgs to 80 feet bgs. Methyl-tert-butyl-ether (MTBE) was not <br /> detected but the detection limits were 160 ppm for the sample collected at 20 <br /> feet bgs, 40 ppm for the samples collected from 30 feet to 70 feet bgs and 8 ppm <br /> for the sample collected from 70 bgs. Analytical results of the grab water sample <br /> were 53,000 parts per billion (ppb) TPH-G, 21,000 ppb, 21000 ppb, 1700 ppb, <br /> and 12,000 ppb BTEX, respectively. MTBE was not detected but the detection <br /> limit was 1,000 ppb. A domestic water well is located approximately 50 feet from <br /> the former UST site, which makes site investigation more urgent. In addition, <br /> this well should be sampled and the water sample analyzed for BTEX, TPH-G, <br /> and MTBE. <br /> The proposed work is to commence by October 21, 1998. Failure to meet this <br /> deadline may result in PHS/EHD requesting formal enforcement action by the <br /> San Joaquin County District Attorney and may jeopardize your eligibility to <br /> receive reimbursement for the costs of the investigation and remediation from <br /> the Fund. <br /> Submit completed permit application for the proposed soil borings and <br /> monitoring well installations along with $89.00 permit fee before beginning work. <br /> Contact PHS/EHD at least 2 working days in advance to schedule field work. <br /> If you have any questions, please feel free to contact Jeffrey Wong at (209) 468- <br /> 0335. <br /> Donna Heran, RENS, Director <br /> Environmental Health Division <br /> Jeffrey Wong, EHS, Trainee Margare Lagorio, REHS <br /> LOP/Site Mitigation Unit IV Supervisor <br /> c: CRWQCB, Central Valley Region - Mark List <br /> c: WHF, Inc. - W. H. Fox <br />