My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE (2)
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SANTA FE
>
23569
>
2900 - Site Mitigation Program
>
PR0541936
>
SITE INFORMATION AND CORRESPONDENCE (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/18/2020 11:15:09 AM
Creation date
5/18/2020 10:55:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0541936
PE
2957
FACILITY_ID
FA0006149
FACILITY_NAME
RANCH MARKET
STREET_NUMBER
23569
Direction
S
STREET_NAME
SANTA FE
STREET_TYPE
RD
City
RIVERBANK
Zip
95376
CURRENT_STATUS
02
SITE_LOCATION
23569 S SANTA FE RD
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
374
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Robert Trommer • Page 5 of 7 <br /> Comments on CUF Site Closure Recommendations for Various Sites March 3, 2010 <br /> With a favorable report, the EHD should be able to start closure process and estimates final <br /> closure will be achieved in six to nine months. <br /> Claim No 14118 - 444 Mossdale Road, Lathrop <br /> Closure for this site is delayed due to problems with the vapor intrusion evaluation. The <br /> consultant utilized soil data for the evaluation ignoring some highly impacted samples and <br /> overestimating the distance of the samples used from the existing building. No justification for a <br /> safe' distance between impacted soil and an existing building was provided. As stated above <br /> for another site, the EHD would like to close this site and believes it should be closed, but as <br /> vapor intrusion has been identified at the State level as a potential health issue that must be <br /> addressed before closing a site, the EHD has been attempting to exercise due diligence by <br /> acquiring defensible data that demonstrates that the health risk posed by potential vapor <br /> intrusion from residual contamination is at or below an acceptable level. The EHD expects this <br /> site may be closed in three to six months. <br /> Claim No 14328 - 1501 W. Charter Way <br /> The closure process for this site has been initiated, and notification documents for the <br /> CVRWQCB are in preparation. The site monitoring wells will need to be destroyed. The EHD <br /> estimates three to six months will be required to complete the closure process for this site. <br /> Claim No 14349 - 517 W. Fremont Street, Stockton <br /> In the 2008 CUF letter, the CUF recommended initiation of groundwater remediation. In 2009, <br /> the CUF recommend site closure although no remediation had been conducted. The EHD had <br /> directed implementation of groundwater remediation and set several dates that were not <br /> complied with. To date, there has been no attempt at active remediation. The plume of <br /> impacted groundwater on the site is delineated, but the EHD believes the contaminant <br /> concentration in well MW-3 to be too high for closure consideration without remediation. <br /> Benzene was present in MW-1 in June 2009 at 4,600 pg/L, TPHg was present at 23,000 pg/L, <br /> and 1,2-dichloroethan (1,2-DCA) at 63 pg/L. The EHD has approved a work plan to install and <br /> test a soil vapor extraction (SVE) well and an in-situ air sparge (IAS) well. As no remediation <br /> has yet been attempted on this site, the EHD believes it would be very beneficial to make such <br /> an attempt and reduce the contaminant mass and accelerate the return to applicable water <br /> quality goals. <br /> Claim No 14353 - 3400 Newton Road, Stockton <br /> This site has an approved work plan (approved by EHD letter dated July 29, 2009) to conduct a <br /> soil vapor extraction test on monitoring wells MW-1 and MW-8, which the EHD expects will <br /> address soil underlying the former tank pit impacted by methyl tert-butyl ether (MTBE) at <br /> concentrations as high as 5.2 milligrams per kilogram (mg/Kg). Groundwater in MW-1 becomes <br /> impacted when groundwater elevation rises into the well and encounters impacted soil currently <br /> in the vadose zone. Groundwater in the surrounding wells is usually not impacted; however <br /> there is a domestic well on the site approximately 134 feet from the former tank pit. The EHD <br /> believes for very little expense the MTBE mass in soil can be reduced which will greatly reduce <br /> the probability that the on-site domestic well will become impacted during a period of high <br /> groundwater elevation and the site is no longer monitored. <br /> On January 29, 2010, the CUF changed the priority class of the site from Class "C" to Class "B." <br /> The EHD anticipates that this will relieve the delay of work on this site and enable the test to be <br /> Comments on CUF Site Closure Recommendations 0310.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.