Laserfiche WebLink
S E C 0 R <br /> !, Mr Michael Infurna—SJCEHD <br /> March 13, 2003 <br /> Page 3 <br /> dated May 13, 2002 The final remediation plan includes 10 soil vapor extraction (SVE) wells and 20 <br /> ozone-sparge wells The SVE wells would be piped to a 500 scfm catalytic oxidizer and the ozone <br /> wells would connect to an ozone-sparging unit <br /> Domestic Wells <br /> Four domestic water supply wells are located within 340 feet of the former tank pit (Figure 2) <br /> Well# Location from Tank Pit Comments <br /> DW-1 90 feet west of tank pit Onsite well <br /> DW-2 120 feet south of tank pit Down gradient well (Well destroyed) <br /> DW-3 245 feet south of tank pit Down gradient of tank pit <br /> DW-4 340 feet south of tank pit Down gradient of tank pit <br /> DW-2R 200 feet south of tank pit Down gradient of tank pit (Well installed <br /> December, 2000) <br /> Water samples collected from domestic wells have been analyzed for the presence of BTEX, TPHg, <br /> five oxygenates, 1,2-dichloroethane (1,2-DCA), and ethylene dibromide (EDB) Since water samples <br /> collected from DW-2 contained reportable concentrations of MtBE, the well was taken out of service <br /> On April 6, 2000, SECOR's field technician interviewed the property owners or renters associated <br /> N with the four domestic water wells and found that water pumped from wells DW-1, DW-3, and DW-4 <br /> was used for irrigation and domestic use All parties interviewed indicated they were drinking bottled <br /> water <br /> Replacement of Domestic Well DW-2 <br /> On January 11, 2001, SECOR oversaw destruction of domestic well DW-2, located south of Ranch <br /> Market (Figure 2) Details of the well destruction are described in SECOR's DW-2 Well Destruction <br /> Report, dated January 23, 2001 <br /> On December 20, 2000, SECOR began oversight of the installation of domestic well DW-2R, the <br /> replacement domestic well for DW-2 From December 28, 2000 to January 5, 2001, the dedicated <br /> well pump, pressure tank, concrete pad, and well-related underground electrical and water service <br /> line was installed Details of the well installation are described in SECOR's Domestic Well <br /> Installation Report(DW 2R), dated February 1, 2001 <br /> On January 8, 2001, SECOR sampled DW-2R and submitted the water sample to Kiff Analytical for <br /> BTEX, TPHg, oxygenates, 1,2-DCA, and EDB using EPA method 82608 The sample was also <br /> analyzed at CLS for nitrate/nitrite using EPA method 300 0 SECOR collected confirmation water <br /> samples from DW-2R on January 11, 2001, and again on January 15, 2001 Analytical data is <br /> summarized in Table 3 <br /> After review of the confirmation samples, the San Joaquin County Environmental Health Department <br /> (SJCEHD) requested the well be brought online On January 18, 2001, SECOR met with Mr <br /> Michael Infurna with SJCEHD for the final inspection of well DW-2R The water service from the <br /> Aero Pure Water supply tank was disconnected and the water valve was opened, allowing DW-2R to <br /> supply water to the home on the Pantoja Property <br /> Riverbank-03-1 Q doc SECOR Intemational Incorporated <br />