Laserfiche WebLink
Quarterly Monitonng and Sampling Report(Q2 2002) 4 <br /> Ranch arket 2 6 to Fe Road Riv rbank aitf rata Jul 2002 <br /> • Replacement of Domestic Well DW-2 <br /> On January 11, 2001, SECOR oversaw destruction of domestic well DW-2, located south of <br /> Ranch Market (Figure 2) Details of the well destruction are described in SECOR's DW-2 Well <br /> Destruction Report, dated January 23, 2001 <br /> On December 20, 2000, SECOR began oversight of the installation of domestic well DW-2R, the <br /> replacement domestic well for DW-2 From December 28, 2000 to January 5, 2001, the <br /> dedicated well pump, pressure tank, concrete pad, and well-related underground electrical and <br /> water service line was installed Details of the well installation are described in SECOR's <br /> Domestic Well Installation Report(DW-2R), dated February 1, 2001 <br /> On January 8, 2001, SECOR sampled DW-2R and submitted the water sample to Kiff Analytical <br /> for BTEX, TPHg, oxygenates, 1,2-DCA, and EDB using EPA method 8250B The sample was <br /> also analyzed at CLS for nitrate/nitrite using EPA method 300 0 SECOR collected confirmation <br /> water samples from DW-2R on January 11, 2001, and again on January 15, 2001 Analytical <br /> data is summarized in Table 3 <br /> After review of the confirmation samples, the San Joaquin County Environmental Health <br /> Department (SJCEHD) requested the well be brought online On January 18, 2001, SECOR met <br /> with Mr Michael Infurna with SJCEHD for the final inspection of well DW-2R The water <br /> service from the Aero Pure Water supply tank was disconnected and the water valve was opened, <br /> allowing DW-2R to supply water to the home on the Pantoja Property <br /> Groundwater Monitoring <br /> Water Table Elevations and Gradient <br /> On April 5, 2002, SECOR personnel measured the depth to water in each of the nine site-related <br /> groundwater monitoring wells (Table 3). MW-7 was inaccessible during the monitoring and <br /> sampling event A water level indicator was used to gauge the wells to the nearest 0 01 foot A <br /> groundwater elevation contour map indicates that groundwater flow is generally toward the south <br /> at a gradient of 0 004 ft/ft (Figure 4) Current and historical groundwater monitoring data are <br /> summarized in Table 3 <br /> Separate-Phase Petroleum Thickness <br /> Well gauging and sampling efforts for the second quarter 2002 did not detect separate-phase <br /> petroleum hydrocarbons (SP) in any of the wells monitored (Table 3) Historically, SP has not <br /> been present in the groundwater monitoring wells at the site <br /> File Ranch MarketlReport\Riverbank-02-2Q <br />