My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SUTTER
>
145
>
2900 - Site Mitigation Program
>
PR0543041
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/18/2020 2:49:26 PM
Creation date
5/18/2020 2:22:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0543041
PE
2960
FACILITY_ID
FA0024604
FACILITY_NAME
HUMAN SERVICES AGENCY
STREET_NUMBER
145
Direction
S
STREET_NAME
SUTTER
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
14912016
CURRENT_STATUS
01
SITE_LOCATION
145 S SUTTER ST
P_LOCATION
01
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
216
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
APPENDIX A - REPORTING 30 August 1991 <br /> e.g., Pump and aerate, spray, pond, RECOMMENDED MINIMUM <br /> thermal incineration, Granulated VERIFICATION ANALYSES (MVA) <br /> Activated Charcoal filtration, etc. <br /> - Proposed discharge, e.g., sewer, Verification analyses for organic chemicals are <br /> storm drain, surface water, land, conducted in laboratories certified by the <br /> reinjection, etc. California Department of Health Services. The <br /> - Permits required with time MVA are based upon the organic chemicals <br /> schedule for application and and mixtures known to be found in under- <br /> turnaround time ground tanks, but are not all inclusive; there- <br /> - Feasibility studies conducted with fore, they tend to have abroad scope. Labora- <br /> results tabulated tory analyses are needed to determine what <br /> - Calculations used to determine the substance (qualitative) and how much (quanti- <br /> efficacy of the system submitted tative) is present in soil and ground water. <br /> for verification The analyses help determine the lateral and <br /> vertical extent of contamination ("zero"line") <br /> Security/Safety measures for excavation which is used to develop an efficient and cost <br /> on-site, contaminated soil piles, pumps effective remediation process. More critically, <br /> and treatment systems. analyses determine whether remediation is <br /> satisfactory (low level analyses required) and <br /> Discussion of FRP the site "cleaned' and stabilized. <br /> To determine that the laboratory is providing <br /> • After approval of the Plan and time schedule, satisfactory service, the in Quality Assur_ <br /> work may proceed. Should delays occur or ance/Quality Control (QA/QC)plans for the <br /> extensions of the time schedule be needed, laboratory must be considered. Quality Assur- <br /> such requests, with supporting documentation, ance includes the policies which direct the <br /> are to be made by letter to the Regional Board laboratory. Quality Control is the physical <br /> and LIA. Quarterly reporting will continue. processing of the sample and is critical for <br /> precise and accurate analyses. Precision and <br /> accuracy, paramount to analytical work, are <br /> Closure increased by improved by QA/QC; however, <br /> Upon successful completion of the FRP activi- <br /> analytical costs also may increase. <br /> ties, and a petition by the tank owner, a letter The costlanalysis table below shows cost <br /> will be prepared by the Regional Board de- ranges for laboratories with offices in Califor- <br /> scribing regulatory conditions of concern to nia, but is not correlated to QA/QC. Based on <br /> the Regional Board or LIA, such as deed Regional Board experience, some of our con- <br /> restrictions, long term monitoring, alternative sistently accurate laboratories with good <br /> drinking water sources, etc. The letter also QA/QC have analytical charges at or near the <br /> will certify or confirm the conditions remain- average cost for the analyses listed. Over the <br /> ing at the site. past four years average costs have increased <br /> about three dollars ($3.00) for BTX&E and <br /> TPH-Gasoline, but have decreased eleven <br /> dollars ($11.00) for TPH-Diesel in soils while <br /> QA/QC generally has improved. <br /> • A-14 <br />
The URL can be used to link to this page
Your browser does not support the video tag.