Laserfiche WebLink
4 0 CONCLUSIONS <br /> Since the previous sampling event in March 2005,concentrations of benzene,total xylene,and TPH-g have <br /> decreased in monitoring well MW-2,while toluene and ethylbenzene levels have risen Concentrations of <br /> BTEX found in monitoring well MW-2A have decreased when compared to the last data set from March <br /> 2005,TPH-g levels have increased slightly These concentrations are consistent with historic concentrations <br /> found in previous sampling events and represent minor fluctuations in contaminant levels No contaminants <br /> of concern were detected in upgradient monitoring well MW-9 <br /> i <br /> i <br /> r <br /> i <br /> ' 5 <br />