My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0010387
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SUTTER
>
145
>
2900 - Site Mitigation Program
>
PR0543041
>
ARCHIVED REPORTS_XR0010387
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/18/2020 3:33:05 PM
Creation date
5/18/2020 3:05:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0010387
RECORD_ID
PR0543041
PE
2960
FACILITY_ID
FA0024604
FACILITY_NAME
HUMAN SERVICES AGENCY
STREET_NUMBER
145
Direction
S
STREET_NAME
SUTTER
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
14912016
CURRENT_STATUS
01
SITE_LOCATION
145 S SUTTER ST
P_LOCATION
01
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table 1-1 <br /> 2005 Sampling Schedule <br /> San Joaquin County Human Services Agency <br /> ' Quarter Monitoring Wells to be Sampled <br /> First MW-2,MW-2A and MW-9 <br /> ' Second MW-2,MW-2A,MW-3A,MWS,MW-6,MW-7 and MW-9 <br /> Third MW-2,MW-2A and MW-9 <br /> ' Fourth MW-2,MW-2A,MW-3A,MW-4,MW-5,MW-6,MW-7,and MW-9 <br /> I <br /> ' 2.0 FIELD SAMPLING SUMMARY <br /> Groundwater samples were collected from monitoring wells MW-2,MW-2A,and MW-9(Figure 1-1)on <br />' March 22,2005 Groundwater sampling field data sheets for the monitoring wells are presented in Appendix <br /> B In addition, an equipment blank water sample was collected and submitted for analysis <br />' Prior to well purging,water levels are measured in all wells to collect data for potentiometric contouring The <br /> standing water volumes within wells scheduled for sampling are calculated using water levels measured in <br /> each well at the time of sampling and total well depths A submersible pump attached to a dedicated <br /> discharge tube is then lowered into the well and used to purge three well casing volumes from each of the <br /> monitoring wells <br />' At the beginning and during the purge process,the temperature,pH,specific conductance,dissolved oxygen, <br /> turbidity,and oxygen reduction potential of the purge water are measured and recorded on a sampling data <br /> sheet The pump is then removed and a disposable bailer is lowered into the well for the collection of <br />' groundwater samples for benzene,toluene,ethylbenzene,and total xylene(BTEX),and for total petroleum <br /> hydrocarbons as gasoline (TPH-g) analysis by United States Environmental Protection Agency (EPA) <br /> Method 8015BI8021 B The groundwater sample is transferred from the disposable bailer into 40-milliliter <br />' (mL) glass sample containers Sample containers containing air bubbles are discarded and recollected <br /> Samples are then sealed in a plastic bag, placed with ice in an insulated chest, and logged on a chain of <br /> custody form for delivery to the analytical laboratory Groundwater sample analyses are performed by <br />' Sequoia Analytical Laboratory in Sacramento, California <br /> The pump used to purge the wells is thoroughly cleaned prior to each use by placing it into a container of tap <br />' water with non-phosphate detergent and washing the outside of the pump Dedicated purge tubing is used <br /> for each well An equipment blank water sample is then collected by pouring laboratory-grade deionized <br /> water over and through the pump into 40-mL glass sample containers The sampling procedure and analysis <br />' then follows that described above to ensure thorough decontamination practices <br /> Purge water from monitoring wells MW-2 and MW-2A is stored in 55-gallon drums staged at the loading <br />' dock of the San Joaquin Human Services Agency building at 145 South Sutter Street, and meets the <br /> requirements for transfer and disposal at a licensed treatment facility Purge water from the remaining <br /> monitoring wells(MW-3A,MW-4,MW-5,MW-6,MW-7,and MW-9)is held in a 500-gallon holding tank, <br /> also staged at the loading dock of the San Joaquin Human Services Agency building at 145 South Sutter <br /> r <br />
The URL can be used to link to this page
Your browser does not support the video tag.