Laserfiche WebLink
` The model presented is interpretational and will be modified as more data is collected The four <br /> ivertical zones identified are as follows (depths are approximate and can vary by several feet across <br />' the site) <br /> Vadose Zone-Extending from surface grade to 54 feet bsg,the depth to the water table The vadose <br />' zone is predominantly fine grained material from surface grade to 54 feet bsg, with a coarse grain <br /> sand unit occurring between 20 feet and 25 feet bsg across a portion of the site The zone is <br /> characterized by low pore pressure <br />' Hydrological Unit 1 (HUI),at the top of the current saturated zone, extends from 54 feet to 80 feet <br /> bsg and is comprised of silty sand to sandy silt and characterized by predominantly high pore <br />' pressure <br /> Hydrological Umt 2 (HU2)extends from 80 to 96 feet bsg, it is composed of an upper I0-foot layer <br />' of fine-grained soil underlain by an approximately 5-foot sand and gravelly sand interval HU2 is <br /> characterized by low pore pressure <br />' Hydrological Unit 3 (HU3)extends from 96 feet bsg to and possibly beyond 134 feet bsg Silt and <br /> clay are the dominant soil type in the interval The interval is characterized by pore pressure <br />' variations from moderate to high pressures <br /> UNDERGROUND STORAGE TANK REMOVAL <br /> Two 550-gallon USTs were removed from the site on 03 October 1986 by Stockton Service Station <br /> Equipment Company According to correspondence from the PHS-EHD,both USTs were reportedly <br /> used to store gasoline Upon removal of the USTs, one soil sample was collected from the floor of <br /> the excavation The sample was analyzed by California Water Labs,Inc , a state-certified analytical <br /> laboratory, for total petroleum hydrocarbons quantified as diesel (TPH-d), benzene, toluene and <br /> xylene <br /> TPH-d and xylene were detected in the soil sample at concentrations of 3,000 parts per million(ppm) <br /> and 0 188 ppm, respectively Benzene and toluene were not detected above the analytical method <br /> reporting limit of 0 010 ppm Based upon results of the soil sample analysis,the PHS-EHD required <br /> tassessment of the lateral and vertical extent of hydrocarbon-impacted soil and/or ground water in the <br /> area of the former UST <br /> PREVIOUS SUBSURFACE INVESTIGATION <br />' On 18 September 1997,five soil probe borings(B-1 through B-5)were advanced at the site to assess <br /> the lateral and vertical extent of petroleum-impacted soil TPH-g was detected in samples from B1, <br />' B3 and B5 at concentrations as high as 14,000 ppm(reported as milligrams per kilogram) Benzene <br /> was detected in only one sample(B 1-40),which contained a concentration of 0 042 ppm Toluene, <br /> ethylbenzene and xylenes were detected in samples from B 1, B3 and B5 at concentrations as high <br /> Advanced GeoEnvironmental,Inc <br />