Laserfiche WebLink
= CAS means Chemical Abstract Services . When the waste code and/or regulated constituents are described as a combination of a chemical vnth its salts and/or esters , the CAS <br /> it number is given for the parent compound only. <br /> Concentration standards for wastewaters are expressed in mgll are based on analysis of composite samples . a <br /> i <br /> ' Except for Cyanides (Total and Amenable) the non-wastewater treatment standards expressed as a concentration were established, in part, based upon incineration in units <br /> operated in accordance with the technical requirements of 40 CFR part 264, subpart 0 or 40 CFR part 265 , subpart 0 , or based upon combustion in fuel substitution units operating in <br /> accordance with applicable technical requirements. A facility may comply with these treatments standards according to provisions in 40 GFR 268 . 40( 4) . All concentration standards <br /> for nonwastewaters are based on analysis of grab samples. <br /> Both Cyanides (Total) and Cyanides (Amenable) for non-wastewaters are to be analyzed using Method 9010 or 9012 , found in "Test Methods for Evaluating Solid Waste , <br /> Physical/Chemical Methods", EPA Publication SW-846 , as incorporated by reference in 40 CFR 260. 11 , with a sample size of 10 grams and a distillation time clone hour and 15 <br /> minutes. <br /> s These constituents are not "underlying hazardous constituents" in characteristic wastes , according to the definition at § 268 . 2 (i) . <br /> Between August 26 , 1996, and August 260 1997s these constituents are not 'underlying hazardous constituents" as defined at §268 . 2 (i) of this Part . l <br /> Note : NA means not applicable . <br /> PLEASE COMPLETE AS APPLICABLE : <br /> 3 <br /> Wastes with organic constituents having treatment standards expressed as concentration levels based in whole or in part on the analytical <br /> detection limit alternative specified in §268.40(d). <br /> ❑ I certify under penalty of law that I have personally examined and am familiar with the treatment technology and operation of the treatment process j <br /> used to support this certification . Based on my inquiry of those individuals immediately responsible for obtaining this information , I believe that the <br /> non-wastewater organic constituents have been treated by combustion units as specified in 268 . 42 . Table 1 . 1 have been unable to detect the <br /> non-wastewater organic constituents , despite having used best good-faith efforts to analyze for such constituents . I am aware there are significant l <br /> penalties for submitting a false certification , including the possibility of fine and imprisonment . <br /> Wastes with treatment standards expressed as concentrations in the waste extract Toxicity Characteristic Leaching Procedure (TCLP). <br /> ❑ I certify under penalty of law that I have personally examined and am familiar with the treatment technology and operation of the treatment process X111 <br /> used to support this certification . Based on my inquiry of those individuals immediately responsible for obtaining this information , I believe that the <br /> treatment process has been operated and maintained properly so as to comply with the treatment standards specified in 40 CFR 268 . 40 without <br /> impermissible dilution of the prohibited waste . I am aware there are significant penalties for submitting a false certification , including the possibility <br /> of fine and imprisonment . <br /> ❑ Alternative Treatment Standard Lab Pack <br /> Manifest Line No . <br /> x <br /> ❑ I certify under penalty of law that I personally have examined and am familiar with the waste and that the lab pack contains only wastes that have not <br /> been excluded under Appendix IV to 40 CFR Part 268 and that this lab pack will be sent to a combustion facility in compliance with the alternative <br /> treatment standards for lab packs at 40 CFR 268 . 42(c). I am aware that there are significant penalties for submitting a false certification , including <br /> the possibility of fine or imprisonment. <br /> i <br /> E3I hereby certify under penalty of law that there are no PCBs ( polychlorinated biphenyls) contained in the oil waste being manifested to Pacific ' <br /> Resource Recovery. I also understand that a sample of the load will be retained and that the generator will be responsible for the clean -up of <br /> contaminated equipment , tanks , etc . if PCBs are present in the waste . <br /> Benzene NESHAP Control Requirement: <br /> For Chemical Manufacturers , Petroleum Refineries , Coke By-Product Facilities and RCRA TSDFs handling wastes subject to 40 CFR 61 subpart FF ONLY: <br /> ❑ This waste is a " Controlled Benzene Waste" which is subject to the notification requirements of 40 CFR 61 Subpart FF , <br /> Manifest Line No , <br /> California List Wastes : <br /> ❑ Liquid hazardous wastes having a pH less than or equal to 2 . 0 t <br /> ❑ Liquid hazardous wastes containing PCBs at a concentration greater than or equal to 50 ppm <br /> ❑ Liquid hazardous wastes that contain HOCs in total concentration greater than or equal to 1000 mg/I <br /> ❑ Nonliquid hazardous wastes containing HOCs in total concentration greater than or equal to 1000 mg/kg <br /> ❑ Free (amenable to chlorination) cyanides greater than or equal to 1000 mg/I <br /> ❑ One or more of the following metals greater than or equal to the following: <br /> Arsenic and/or compounds : 500 mgll <br /> Cadmium and/or compounds : 100 mg/I <br /> Chromium and/or compounds : 500 mg/I <br /> Lead and/or compounds: 500 mgll <br /> Mercury and/or compounds : 20 mg/I <br /> Nickel and/or compounds : 134 mg/I <br /> Selenium and/or compounds : 100 mg/I <br /> Thallium and/or compounds : 130 mg/I <br /> .a <br /> Pa <br /> 9a 3 0/ 4 <br />