Laserfiche WebLink
ENVIRONMENIAC� <br /> Analytical Chemists <br /> March 27, 2020 <br /> Frank C Alegre Trucking Inc. Lab ID : STK2032768 <br /> P. O. Box 1508 Customer 3-13002 <br /> Lodi, CA 95241 <br /> Laboratory Report <br /> Introduction: This report package contains total of 8 pages divided into 3 sections: <br /> Case Narrative (2 pages) : An overview of the work performed at FGL. <br /> Sample Results (2 pages) : Results for each sample submitted. <br /> Quality Control (4 pages) : Supporting Quality Control (QC)results. <br /> Case Narrative <br /> This Case Narrative pertains to the following samples: <br /> Sample Description Date Sampled R Dat ed FGL Lab ID # Matrix <br /> Media-Box 02/26/2020 02/26/2020 1 STK2032768-001 Sld <br /> Media-Bag 02/26/2020 02/26/2020 STK2032768-002 Sld <br /> Sampling and Receipt Information: All samples were received in acceptable condition and within <br /> temperature requirements, unless noted on the Condition Upon Receipt(CUR) form. All samples arrived <br /> on ice. All samples were prepared and analyzed within the method specified hold time. All samples were <br /> checked for pH if acid or base preservation is required(except for VOAs). For details of sample receipt <br /> information,please see the attached Chain of Custody and Condition Upon Receipt Form. <br /> Quality Control: All samples were prepared and analyzed according to the following tables: <br /> Inorganic-Metals QC <br /> 02/28/2020:202330 All preparation quality controls are within established criteria(performed at FGL-SP <br /> ELAN 1573),except: <br /> The following note applies to Antimony,Thallium: <br /> 435 Sample matrix may be affecting this analyte.Data was accepted based on the LCS or CCV recovery. <br /> 3050 The following note applies to Antimony: <br /> 435 Sample matrix may be affecting this analyte.Data was accepted based on the LCS or CCV recovery. <br /> The following note applies to Barium,Antimony,Thallium,Zinc: <br /> 430 Post Digestion Spike(PDS)not within Acceptance Range(AR)because of matrix interferences <br /> affecting this analyte.Data was accepted based on the LCS recovery. <br /> 03/05/2020:203811 All analysis quality controls are within established criteria,except: <br /> 6010B The following note applies to Copper: <br /> 220 The CCB was greater than the DQO.However,all results were either five times greater than the CCB <br /> concentration or ND relative to the PQL. <br /> Page 1 of 8 <br /> Corporate Offices&Laboratory Office&Laboratory Office&Laboratory Office&Laboratory Office&Laboratory <br /> 853 Corporation Street 2500 Stagecoach Road 563 E.Lindo Avenue 3442 Empresa Drive,Suite D 9415 W.Goshen Avenue <br /> Santa Paula,CA 93060 Stockton,CA 95215 Chico,CA 95926 San Luis Obispo,CA 93401 Visalia,CA 93291 <br /> TEL:(805)392-2000 TEL:(209)942-0182 TEL:(530)343-5818 TEL:(805)783-2940 TEL:(559)734-9473 <br /> Env FAX:(805)525-4172/Ag FAX:(805)392-2063 FAX:(209)942-0423 FAX:(530)343-3807 FAX:(805)783-2912 FAX:(559)734-8435 <br /> CA ELAP Certification No.1573 CA ELAP Certification No.1563 CA ELAP Certification No.2670 CA ELAP Certification No.2775 CA ELAP Certification No.2810 <br />