Laserfiche WebLink
Page: 6 <br />' Company: IT Corporation, Martinez IT ANALYTICAL SERVICESSAN JOSE, CA <br /> Date: 01/21/92 <br /> Client Work ID: 190916 Pac Bell E042 Work Order: T1-12-081 <br /> TEST NAME: Petroleum Hydrocarbons <br /> SAMPLE ID: MW3--4 <br />' SAMPLE DATE: 12/08/91 <br /> LAB SAMPLE ID: T112081-05 <br /> SAMPLE MATRIX: solid <br /> RECEIPT CONDITION: Cool <br /> RESULTS in Milligrams per Kilogram: <br />' EXTRACTION ANALYSIS <br /> METHOD DATE DATE <br /> BTEX 8020 12/12/91 12/16/91 <br /> Low Boiling Hydrocarbons Mod.8015 12/12/91 12/16/91 <br /> High Boiling Hydrocarbons Mod.8015 12/11/91 12/16/91 <br /> DETECTION <br /> PARAMETER LIMIT DETECTED <br /> Low Boiling Hydrocarbons <br /> calculated as Gasoline 1.0 7.4 <br /> BTEX <br /> Benzene 0.005 None <br /> Toluene 0.005 None <br /> Ethylbenzene 0.005 0.006 <br />' Xylenes (total) 0.005 0.013 <br /> High Boiling Hydrocarbons <br /> calculated as Diesel 1.0 None <br /> SURROGATES $ REC <br /> 1,3-Dichlorobenzene (Gasoline) 234,* <br /> 1,3-Dichlorobenzene (BTEX) 141.* <br /> 1nC32 (Diesel) 62. <br /> Comments: <br /> Compounds detected and calculated as low boiling hydrocarbons <br /> are due to a petroleum mixture other than gasoline. <br /> * Hydrocarbon interferences, instrument standard okay. <br /> 682 1 89 <br />