ARCHIVED REPORTS_XR0009350
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
345
>
3500 - Local Oversight Program
>
PR0545671
>
ARCHIVED REPORTS_XR0009350
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2020 12:08:30 PM
Creation date
5/19/2020 11:54:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0009350
RECORD_ID
PR0545671
PE
3528
FACILITY_ID
FA0003959
FACILITY_NAME
AT&T CALIFORNIA - UE042
STREET_NUMBER
345
Direction
N
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
02
SITE_LOCATION
345 N SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INTERNATIONAL TECHNOLOGY CORPORATION <br /> Ms Mary Maeys 3 January 15, 1996 <br />' currently exists, however, the 96 ppb modeled value is below the 100 ppb <br /> SNARL value No detectable concentrations of the regulated BTEX <br />' constituents have ever been encountered in any of the Location 2 samples. <br /> Copies of the input files, graphical, and tabular V-Leach modeling results are <br /> enclosed in Attachment 4 0 <br />' Issue D Provide calculation sheets for each location (pages 8 and 10 of IT Site Closure <br /> Recommendation Report, April 1995) and verify conversion factor of 7.48 <br />' gal/1 fe. <br /> Response D Calculation sheets for the average residual diesel volume for Location 1 <br /> (beneath the abandoned USTs in the building basement) can be found in <br /> Attachment 10 of this report. <br />' The table listing current analytical data for Location 2 (beneath the Lindsay <br /> Street sidewalk), which was used to define the maximum current diesel fuel <br /> concentration, is provided in Attachment 2.0 of this report <br /> Calculation sheets for the average historical residual diesel volume for <br /> Location 2 (beneath the Lindsay Street sidewalk) can be found in Attachment <br /> 3 0 of this report <br />' Figures depicting the plan view and cross-sectional views of Locations 1 and 2, <br /> which were used to calculate the volume of impacted sod., are provided in the <br /> "Figures" attachment of this report. <br />' The reference for the conversion factor used in the maximum volume of <br /> residual diesel in soil calculations (pages 8 and 10 of the IT Site Closure <br />' Recommendation Report) is provided in Attachment 5 0 of this report. <br /> Issue E Explain the rationale for applying ethylbenzene and xylene concentrations to <br /> modeled areas <br /> Response E Table 1, contained in Attachment 1.0 of this report, is a summary of all <br /> ' analytical data collected to date at Location 1 (near abandoned USTs in <br /> building basement). A total of seven samples were analyzed for benzene, <br /> toluene, ethyl benzene, and xylenes (BTEX). Of these seven samples, only <br /> three contained detectable xylenes and only one contained detectable ethyl <br /> benzene No detectable benzene or toluene concentrations were encountered. <br /> As only one concentration of ethyl benzene was encountered, this value was <br /> ' used for modeling purposes. Since three detectable xylene concentrations were <br /> encountered, the greatest detected concentration was used during modeling. <br />