My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
2050
>
2200 - Hazardous Waste Program
>
PR0514483
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2020 3:24:15 PM
Creation date
5/19/2020 1:40:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0514483
PE
2228
FACILITY_ID
FA0010987
FACILITY_NAME
TEC Equipment
STREET_NUMBER
2050
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
Ave
City
Lathrop
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
2050 E Louise Ave
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 11 � I I ft1 Environmental Health Department <br /> COLENTY IY <br /> C,rearneic mows mere, <br /> Large Quantity Hazardous Waste Generator Compliance Review Report <br /> Facility Name and Address: TEC Equipment, 2050 E Louise Ave, LATHROP 95330 <br /> information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly <br /> responsible for gathering the information,the information submitted is,to be the best of my knowledge and belief,true, <br /> accurate, and complete. I am aware that there are significant penalties for submitting false information, including the <br /> possibility of fine and imprisonment for knowing violations. <br /> Title 22 California Code of Regulations section 66265.192(k) <br /> The tank system assessment shall include all of the following information: <br /> (1)tank configuration (i.e., horizontal,vertical), material of construction, and gross capacity(in gallons); <br /> (2)design standard(s), if available, according to which the tank and ancillary equipment were or will be constructed and all <br /> of the following information: <br /> (A)material of construction; <br /> (B)material thickness and the method used to determine the thickness; <br /> (C)description of tank system piping (material, diameter); <br /> (D)description of any internal and external pumps; and <br /> (E)sketch or drawing of tank including dimensions. <br /> (3)documented age of the tank system (if tank was previously used), if available, (otherwise, an estimate of the age); <br /> (4)description and evaluation of any leak detection equipment; <br /> (5)description and evaluation of any corrosion protection equipment, devices, or material; <br /> (6)description and evaluation of any spill prevention or overfill equipment; <br /> (7)description and evaluation of secondary containment for the tank system (secondary containment must meet minimum <br /> standards as specified in subsections 0)(1)through 0)(3)of this section)including applicable secondary containment for <br /> ancillary equipment as required in subsection 66265.193(f); <br /> (8)hazardous characteristics of the waste(s)that have been or will be handled; <br /> (9)prior to placing a new tank system or component in use, an independent, qualified installation inspector or an <br /> independent, qualified, professional engineer, registered in California, either of whom is trained and experienced in the <br /> proper installation of tank systems, shall inspect the system or component for the presence of any of the following items and <br /> document in writing the results of the inspection: <br /> (A)weld cracks or breaks; <br /> (B)scrapes of protective coatings; <br /> (C)corrosion; <br /> (D)any structural damage or inadequate construction or installation such as cracks, punctures, damaged fittings.All <br /> discrepancies shall be documented in the assessment and remedied before the tank system is placed in use. <br /> (10)all new tanks and ancillary equipment shall be tested for tightness prior to being placed in use.The results of the test(s) <br /> shall be documented in this assessment.Tank system integrity or leak test requirements must be in compliance with all local <br /> requirements. Prior to conducting a tank system integrity test or leak test, contact local agency staff for local requirements. <br /> (11)estimated remaining service life of the tank system based on findings of subsections (k)(1)through (k)(10). <br /> Title 22 California Code of Regulations section 66265.1920) <br /> (1)tank system must have secondary containment capable of containing 100 percent of the contents of the tank and <br /> ancillary piping volume; and <br /> (2)if the tank system is exposed to precipitation,the secondary containment system must have sufficient capacity, in <br /> addition to that required in subsection 0)(1)of this section,to contain run-on and infiltration from a 25-year, 24-hour rainfall <br /> event; <br /> (3)tank system secondary containment shall be provided with a leak detection system that is designed and operated so that <br /> it will detect either the failure of the primary and secondary containment structure or any release of hazardous waste or <br /> accumulated liquid in the secondary containment system within 24 hours, or at the earliest practicable time if the existing <br /> detection technology or site conditions will not allow detection of a release within 24 hours. <br /> Title 22 California Code of Regulations section 66265.193(b-c) <br /> (b)Secondary containment systems shall be: <br /> FA0010987 PR0514483 SCO21 05/01/2020 <br /> Rev.04/11/2019 Page 5 of 7 Large Quantity Hazardous Waste Generator Compliance Review Report <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.