My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1469
>
2300 - Underground Storage Tank Program
>
PR0231126
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2020 4:27:09 PM
Creation date
5/19/2020 2:59:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231126
PE
2361
FACILITY_ID
FA0001570
FACILITY_NAME
UNITED # 5447
STREET_NUMBER
1469
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
08818030
CURRENT_STATUS
01
SITE_LOCATION
1469 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
138
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJI Environmental Health Department <br /> COL) NTY Time In: <br /> Time Out: <br /> rrrws Ter!. <br /> Underground Storage Tank Program Service Request Inspection Report <br /> Name of Facility: UNITED #5447 Date: 01/07/2020 <br /> Address: 1469 E HAMMER LN , STOCKTON 95210 <br /> Requestor: MATT THOMAS, CGRS, INC. Telephone: (626) 627-8316 <br /> Program Element: 2308- UST RETROFIT Request#: SR0081071 <br /> Inspection Type: 298- UST RETROFIT REPAIR INSPECTION <br /> Onsite Service Technician: Leonardo Rangel ICC Service Tech/Installer Exp. Date: 06/16/2020 <br /> Manufacturer training: OPW,03/14/20 <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> NOTES <br /> On site for Corrosion protection: <br /> -Verified corrosion protection for 87, 89 and diesel direct bury spill buckets prior to backfilling. <br /> Still needed <br /> -Spill bucket one hour hydrostatic test <br /> -Verification of 5 gallon capacity <br /> -Verification of proper drainage <br /> - Measurement of drop tubes <br /> -Verification of flapper functionality <br /> -Verification of ball floats <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code. If a reinspection is required,fees will be assessed at the current hourly rate. <br /> U � r <br /> Received by: Name and Title: Leonardo Rangel, Service Tech <br /> EH Specialist: PAUL NSO Phone: (209)468-3432 <br /> FA0001570 SR0081071 SC298 01/07/2020 <br /> EHD 23-01 Rev.06/30/15 Page 1 of 1 Underground Storage Tank Program Service Request Inspection Report <br />
The URL can be used to link to this page
Your browser does not support the video tag.