My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1469
>
2300 - Underground Storage Tank Program
>
PR0231126
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2020 4:27:09 PM
Creation date
5/19/2020 2:59:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231126
PE
2361
FACILITY_ID
FA0001570
FACILITY_NAME
UNITED # 5447
STREET_NUMBER
1469
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
08818030
CURRENT_STATUS
01
SITE_LOCATION
1469 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
138
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM (Page 6 of 6) <br /> XXI . UNDER-DISPENSER CONTAINMENT TESTING INFORMATION <br /> Manufacturer(s) : Identify UDC ID from section III for each Manufacturer <br /> S . Bravo Systems 1 -2 3 =4 5-6 7=8 9 -10 11 -12 <br /> Test Method Used : <br /> ❑ Manufacturer Guidelines : (Specify) <br /> ® Industry Code or Engineering Standard : (Specify) RPA 200 / Guidelines Adopted by CAL CUPA Forum <br /> ❑ Engineered Method : (Specify) <br /> Attach the testing procedures and all documentation required to determine the results. # of Attached Pages <br /> 1 <br /> UDC Testing Training and Certifications (List applicable certifications.) Expiration Date <br /> ICC California Service Technician UT Cert. #8185019 09/ 10/2021 <br /> Franklin Fueling Systems Incon TS -STS Sump Tester Level 4 Cert . #1000553709 01 /03/2022 <br /> XXII , COMMENTS <br /> Provide any additional comments here. <br /> 1 . UDC #1 -2 & #3=4 both failed hydrostatic sump testing . Visual failures at shallow Bravo 82000 electrical penetrations . <br /> Recommended repairs are to install Bravo 's 82000 retro -fit kits at each UDCs . <br /> 2 . UDC #9-10 failed hydrostatic sump testing . Visual failures at 87 product line secondary termination test boot. <br /> Recommended repairs are to replace test boot with Icon ISR 3 .5x2 .40SA. <br /> If the facility has more components than this form accommodates, additional copies of these pages may be attached. <br /> CERS = California Environmental Reporting System , ID = Identification , UST = Underground storage tank, ICC = International Code Council, <br /> NA = Not applicable, UDC = Under-dispenser containment <br />
The URL can be used to link to this page
Your browser does not support the video tag.