My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1469
>
2300 - Underground Storage Tank Program
>
PR0231126
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2020 4:27:09 PM
Creation date
5/19/2020 2:59:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231126
PE
2361
FACILITY_ID
FA0001570
FACILITY_NAME
UNITED # 5447
STREET_NUMBER
1469
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
08818030
CURRENT_STATUS
01
SITE_LOCATION
1469 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
138
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1 ) <br /> Type of Action ❑ Installation Inspection ❑x Repair Inspection ❑ 36 Month Inspection <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10180781 1 /8/2020 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> United Pacific #5447 <br /> Business Site Address City ZIP Code <br /> 1469 E Hammer Ln Stockton 95210 <br /> I1 . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification) Phone # <br /> Garrett Warren <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> CSLB#803616 8185019 9/20/2021 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br /> Veeder- Root B42126 exp . 1 -21 -21 OPW EVR 101018 exp . 6-5-21 <br /> III . OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ❑ Manufacturer Guidelines (Specify) : <br /> Used : <br /> ❑x Industry Code or Engineering Standard (Specify) : RP1200 <br /> ❑ Engineered Method (Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages <br /> TANK ID : (By tank number, storedproduct, etc) T1 : 91 T2 : 89 T3 : 87 T4 : Diesel <br /> What is the tank inside diameter? (Inches) 120 120 " 120 " 120" <br /> Is the fill piping secondarily contained ? ❑ Yes ❑x No ❑ Yes 0 No ❑ Yes ❑x No ❑ Yes Z No <br /> Is the vent piping secondarily contained? ❑ Yes 2 No ❑ Yes n No ❑ Yes El No ❑ Yes 0 No <br /> Overfill Prevention Equipment Manufacturer(s) oPw oPW opw oPW <br /> What is the overfill prevention equipment response ❑x Shuts Off Flow ❑x Shuts Off Flow ❑x Shuts Off Flow Shuts Off Flow <br /> when activated ? ❑x Restricts Flow �9 Restricts Flow Z Restricts Flow n Restricts Flow <br /> (Check all that apply.) <br /> ❑ A/V Alarm ❑ A/V Alarm ❑ AIV Alarm ❑ AIV Alarm <br /> Are flow restrictors installed on vent piping ? ❑ Yes 0 No ❑ Yes [E No ❑ Yes H No ❑ Yes 0 No <br /> At what level in the tank is the overfill prevention set <br /> to activate? (Inches from bottom of tank.) 104 . 75 „ 104 . 75 „ 104 . 75 „ 104 . 75 „ <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 94 % 94 % 94 % 94 % <br /> Is the overfill prevention in proper operating condition ❑x Yes ❑x Yes 0 Yes El Yes <br /> to respond when the substance reaches the <br /> appropriate level? El No (Specify in V.) [INo (Specify in V.) El No (Specify in V) El No (Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results Q Pass ❑ Fail ❑x Pass ❑ Fail 0 Pass ❑ Fail 0 Pass ❑ Fail <br /> V. COMMENTS <br /> Any items marked "Fail' must be explained in this section. Any additional comments may also be provided here. <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipmentwas inspected in accordance with California Code of Regulations , Title 233 <br /> Division 3 , Chapter 16 , Section 2637 . 2 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> If the facility has more components than this form mccommodates, additional copies of this page maybe attached. <br /> CERS = Califomia Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = International Code Council, AN = Audible and Visual <br />
The URL can be used to link to this page
Your browser does not support the video tag.