My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3202
>
2300 - Underground Storage Tank Program
>
PR0231129
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/5/2021 2:12:42 PM
Creation date
5/19/2020 3:05:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231129
PE
2361
FACILITY_ID
FA0001817
FACILITY_NAME
7-ELEVEN INC #35355
STREET_NUMBER
3202
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95209
CURRENT_STATUS
01
SITE_LOCATION
3202 W Hammer Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
143
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM ( Page1 of 6) <br /> This form must be used to document testing and servicing of underground storage tank ( UST) monitoring equipment. A copy <br /> of this form must be provided to the UST owner or operator. The owner or operator must submit a copy of this form to the <br /> local agency regulating the USTs within 30 days of the date of the monitoring system certification . <br /> in FACILITYINFORMATION NOMMONOWNE <br /> CERS ID Date of Monitoring System Certification <br /> 10166191 2/6/2020 <br /> Business Name (Same as Facility Name or DBA- Doing Business As . ) Building # <br /> 7 ELEVEN 35355 <br /> Business Site Address City . Zip : <br /> 3202 W HAMMER LANE (W136) STOCKTON 95209 <br /> II , UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of Company Performing the Certification Phone # <br /> TANKNOLOGY INC . (800) 8004633 Ext . <br /> Mailing Address <br /> 11000 N . Mopac Expressway #500 , Austin , TX 78759 <br /> Name of UST Service Technician Performing the Certification (Print as shown on the ICC Certification .) <br /> Jesus Saldivar <br /> Contractor/Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> Class A General Engineering 743160777 8361393 6/13/2021 <br /> Monitoring System Training and Certifications (List all applicable certifications .) Expiration Date <br /> Tanknology Certification Level III ATG Operability Training Certification Exam 115235 12/31 /2022 <br /> ICC CA UST Service Technician 8361393 06/13/2021 <br /> Veeder Root VR Level 4 845334 04!28/2021 <br /> VMI TLDT-5000 Tester 3802 11 /12!2021 <br /> III . RESULTS OF TESTING/SERVICING ' <br /> Indicate and attach the following reports if the monitoring equipment is capable of generating either. Y N NA ' <br /> C Monitoring System Set-up W' Alarm History Report <br /> Was any monitoring equipment replaced ? r r <br /> (If "Yes, "identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV below.) <br /> Was damage , debris , or liquid found inside any secondary containment systems? r (V r <br /> (If "Yes, " describe what was found in section IV below.) <br /> Is all monitoring equipment operational per manufacturer' s specifications? r I® <br /> (If " No , " describe why in section IV below.) <br /> IV. COMMENTS <br /> If directed to use this section, describe how and when the issues were or will be corrected. <br /> V. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the equipment identified in this document was inspected/serviced in accordance with California Code of <br /> Regulations , title 23 , division 3 , chapter 16 , section 2638 and all information contained herein is true and accurate . Attached <br /> to this certification is information (e. g . , manufacturers' checklists , monitoring system set-up , alarm history report, etc . ) <br /> necessary to verify that this information and the site plan showing the layout of UST system is complete and accurate . <br /> UST Service Technician Signature <br /> /�4wjw� <br /> CERS=California Environmental Reporting System , ID=Identification, UST= Underground storage tank, ICC=International Code Council <br />
The URL can be used to link to this page
Your browser does not support the video tag.