My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SCOTTS
>
908
>
2900 - Site Mitigation Program
>
PR0536958
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/20/2020 12:15:40 PM
Creation date
5/20/2020 11:07:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0536958
PE
2950
FACILITY_ID
FA0021221
FACILITY_NAME
SCOTT AURORA INC
STREET_NUMBER
908
Direction
E
STREET_NAME
SCOTTS
STREET_TYPE
AVE
City
STOCKTON
Zip
95203
APN
15130001
CURRENT_STATUS
01
SITE_LOCATION
908 E SCOTTS AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
277
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Q <br /> Limited Phase 11 Subsurface Investigation Report <br /> 902-908 East Scotts Avenue <br /> Stockton,California a ntea g ro u p <br /> Antea Group Project No. UPR82572A <br /> 3.3.6 Pesticides <br /> The laboratory tested a total of 8 soil samples for pesticides. None of the samples submitted had concentration <br /> detected above the LRL. Table 4 includes a summary of the analytical data for pesticides. <br /> 3.4 Quality Assurance/Quality Control (QA/QC) <br /> QA/QC measures included laboratory method blanks and quality control (QC)samples and a QA/QC data validation <br /> check on the laboratory's analytical results for the samples collected on April 12-13, 2012. The laboratory report is <br /> included as Appendix C. The following table summarizes Antea Group's review of the QA/QC results. <br /> Laboratory QA/QC Performed: Yes <br /> Laboratory method blanks and quality control Yes,two data qualifiers were noted^ <br /> samples analyzed: <br /> Are the data valid for their intended purpose? Yes <br /> Explanations: <br /> ^Qualifier"X"=Surrogate is outside control limits <br /> ^Qualifier"D"=Surrogate or matrix spike recoveries were not obtained because the extract was diluted for analysis;also compounds analyzed at <br /> a dilution may be flagged with a D. <br /> Based on a review of the laboratory's analytical reports, including the laboratory QA/QC procedures and those <br /> implemented by Antea Group, we conclude that the laboratory data obtained during this soil sampling event are <br /> valid and usable for their intended purpose. <br /> 4.0 CONCLUSIONS AND RECOMMENDATIONS <br /> On April 12-13,2012,Antea Group and subcontractors completed a limited,shallow soil sampling event at the 902- <br /> 908 East Scotts Avenue property located in Stockton, California. Antea Group's subcontractor advanced a total of <br /> 20 soil test borings by hand auger and direct-push rig at the locations depicted on Figure 3. Antea Group <br /> field-screened soil samples and collected a minimum one sample from each boring for submittal to a state- <br /> certified laboratory for analysis by one or more of the contaminants of concern listed in Section 3.2.3. <br /> • Field screening of shallow soils indicated elevated PID readings at B3, B6, B7, and B15. Laboratory data <br /> indicated that certain soil contaminants, including VOCs and petroleum constituents, are present at <br /> concentrations greater than industrial screening criteria in shallow soils at B3 and B7, coinciding with the <br /> higher PID readings. <br /> • Laboratory analytical results indicate that VOCs, PCBs, and pesticides do not appear to be a significant or <br /> widespread environmental concern at the site. However, a trace level of PCBs reported in B7 could <br /> indicate a greater concern in that area of the property. The PCB detection coincides with the highest <br /> levels of petroleum reported in this investigation. <br /> • Trace to low-level PAH concentrations appear scattered across the site in shallow soils. This may be an <br /> artifact of the historical industrial usage of the property or a condition of shallow soils used for site <br /> 9 www.anteagroup.com <br />