My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0012624
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SCOTTS
>
1033
>
3500 - Local Oversight Program
>
PR0545679
>
ARCHIVED REPORTS_XR0012624
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/20/2020 12:14:06 PM
Creation date
5/20/2020 11:50:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0012624
RECORD_ID
PR0545679
PE
3528
FACILITY_ID
FA0005644
FACILITY_NAME
ATCHISON TOPEKA & SANTA FE RR*
STREET_NUMBER
1033
Direction
E
STREET_NAME
SCOTTS
STREET_TYPE
AVE
City
STOCKTON
Zip
95205
CURRENT_STATUS
02
SITE_LOCATION
1033 E SCOTTS AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
410
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
x. <br /> I <br /> GROUNDWATER TECHNOLOGY <br /> STANDARD OPERATING PROCEDURE <br /> CONCERNING OPERATION/CALIBRATION OF <br /> PHOTOIONIZATION ANALYZER <br /> r• SOP 14 <br /> The HNU Model 101 Photoionisation Analyzer shall be <br /> used to measure the concentration of trace gases over a <br /> range of less than 1 ppm to 21000 ppm by employing the <br /> principle of Photoionization for detection. The <br /> specific instrument used for investigations related to <br /> hydrocarbon contamination should be calibrated for <br /> direct readings in parts per million (ppm) volume/volume <br /> of benzene. This portable field analyzer consists of <br /> -. two components (1) probe which contains a fan for moving <br /> air into the sensor, an ultraviolet light (provides <br /> ionization energy), an ionization chamber and signal <br /> amplifer (2) readout assembly which contains a battery, <br /> ion chamber bias, meter readout and control panel. <br /> Specifics of the detection principle/theory and functions <br /> of various components can be found in the manufactures <br /> instruction manual (HNU Systems, Inc. ). <br /> To assure optimum performance, the photoionization analy- <br /> zer should be calibrated with a standard gas mixture of <br /> known concentration from a pressurized container. A <br /> daily procedure for calibration involves bringing the <br /> probe and readout in close proximity to the calibration <br /> gas, cracking the valve on the tank and checking the <br /> .. instrument reading. This provides a useful spot check <br /> for the instrument. <br /> A procedure conducted weekly for more accurate calibra- <br /> tion of the instrument from a pressurized container is <br /> to connect one side of a "T" to the pressurized container <br /> i~ of calibration gas, •'another side of the "T" to a rotameter <br /> �.• and the third side of the "T" directly to the S" extension <br /> to the photoionization probe (see Figure 2). Crack the <br /> valve of the pressurized container until a slight flow is <br /> indicated on the rotameter. The instrument draws in the <br /> volume of sample required for detection, and the flow in <br /> the rotameter indicates an excess of sample. Now adjust <br /> the span pot so that the instrument is reading the exact <br /> value of the calibration gas. (If the instrument span <br /> setting is changed, the instrument should be turned back <br /> to the standby position and the electronic zero should <br /> be readjusted, if necessary). <br /> GROUNDWATER <br /> TECHNOLOGY,INC. <br /> CONSULTING GROUNDWATER GEOLOGISTS <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.