My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
1210
>
2200 - Hazardous Waste Program
>
PR0518573
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/17/2020 2:48:11 PM
Creation date
5/20/2020 2:45:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0518573
PE
2226
FACILITY_ID
FA0013981
FACILITY_NAME
BRAKEMASTERS #163
STREET_NUMBER
1210
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1210 TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S0 JOA U 1 Environmental Health Department <br /> U ; i y <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> BRAKEMASTERS#163 1 1210 TRACY BLVD,TRACY March 18, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 66262.34(d)(2)No emergency coordinator. <br /> OBSERVATION: A complete modified contingency plan with an assigned emergency coordinator was not posted at <br /> the facility. <br /> -Emergency coordinator for modified contingency plan is not up to date, employee no longer works for facility. <br /> REGULATION GUIDANCE: The emergency coordinator or his designee must respond to any emergencies that <br /> arise. The business operator must post the following information next to telephones or in areas directly involved in <br /> the generation and accumulation of hazardous waste: the name and emergency telephone number of the <br /> emergency coordinator,the location of fire extinguishers and spill control material, and the telephone number of the <br /> fire department unless the facility has a direct alarm. <br /> CORRECTIVE ACTION: Immediately update emergency coordinator for contingency at the facility. Provide a <br /> statement to the San Joaquin County Environmental Health Department that the correction is complete. <br /> This is a repeat violation, Class II. <br /> 303 CCR 66262.34(d)(2) Failed to maintain all communication or alarm systems, spill control, or decontamination <br /> equipment. <br /> OBSERVATION: The following were observed in the hazardous wastes storage area: <br /> -Secondary containment for one 55-gallon drum with waste antifreeze and one 55-gallon drum with used oil <br /> observed with approximately 2 inches of used oil accumulating inside. <br /> REGULATION GUIDANCE:All facility communications or alarm systems,fire protection equipment, spill control <br /> equipment, and decontamination equipment,where required, shall be tested and maintained as necessary to assure <br /> its proper operation in time of emergency. <br /> CORRECTIVE ACTION: Bring the secondary containment for waste antifreeze and used oil into proper working <br /> order by repair, replacement or testing. Provide a corrective action statement to the San Joaquin County <br /> Environmental Health Department within 30 days. <br /> This is a minor violation. <br /> FA0013981 PR0518573 SCO01 03/18/2020 <br /> EHD 22-01 Rev.9/20/2019 Page 4 of 8 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.