Laserfiche WebLink
I - <br /> 1 Quarterly Report - Fourth Quarter 2004 <br /> LANGSTON'S MARKET <br />' 15615 South 7" Street,Lathrop, Cahfornla <br />' 1.0. INTRODUCTION <br /> At the request of Mr James Langston of Langston's Market,Advanced GeoEnvlronmental, Inc <br />' (AGE)has prepared this quarterly report for the property located at 15615 South 7`h Street,Lathrop, <br /> California The scope of work Included the performance of a quarterly ground water monitoring <br /> event and preparation of this report The location of the site and surrounding area are Illustrated on <br />' Figure 1 Structures, soil borings, and monitoring well locations are illustrated on Figure 2 Details <br /> of previous investigations are summarized in Appendix A <br /> 1 <br /> 2.0. PROCEDURES <br />' On 22 December 2004, a quarterly ground water monitoring event was performed at the site Field <br /> work was conducted in accordance with Central Valley Regional Water Quality Control Board <br />' (CVRWQCB) and San Joaquin County Environmental Health Department (EHD) guidelines for <br /> Investigating underground storage tank (UST) sites and sampling ground water monitoring wells, <br /> respectively <br /> 2 1 WELL MONITORING AND EVACUATION <br /> A Solmst water level meter was used to measure the depth to ground water in ground water <br /> monitoring wells MW-1 through MW-8 relative to the tops of the well casings The ground water <br />' elevations and gradient were determined from this data (Table 1) <br /> After recording water level measurements,a dedicated,disposable plastic bailer was used to evacuate <br />' (purge) each monitoring well of standing water Approximately 5 to 18 5 gallons of water were <br /> removed from wells MW-2 through MW-8 Monitoring well MW-1 was purged dry after 6 gallons <br />' of water had been evacuated Ground water temperature, pH, and conductivity were measured at <br /> regular intervals during the purge process using an Oakton water analyzer Field data sheets are <br /> included in Appendix B Purged water was stored on-site in properly labeled, Department of <br />' Transportation(DOT)-approved 55-gallon drums <br />' 22 COLLECTION AND ANALYSIS OF GROUND WATER SAMPLES <br /> Following purging, the depth to ground water was re-measured to ensure that a minimum of 80% <br />' well-volume recharge had been achieved prior to sampling Water samples were collected from each <br /> purged well using the dedicated, disposable plastic bailer Each water sample was transferred into <br /> three laboratory-supplied,40-milliliter(ml)volatile organic analysis(VOA)vials containing 0 5 ml <br />' Advanced GcoEnvironmental,Inc <br /> 1 <br />