My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6425
>
2300 - Underground Storage Tank Program
>
PR0231211
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/5/2021 1:26:49 PM
Creation date
5/21/2020 12:39:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231211
PE
2371
FACILITY_ID
FA0002409
FACILITY_NAME
SAFEWAY FUEL CENTER #2707
STREET_NUMBER
6425
Direction
N
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
6425 N PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
196
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1 ) <br /> TypeAt ❑ Installation Inspection ❑ Repair Inspection ® 36 Month Inspection <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10120456 1 /3/20 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> Safeway 2707 <br /> Business Site Address City ZIP Code <br /> 6425 Pacific Ave Stockton 95207 <br /> Il . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) Phone # <br /> Steven White (408) 971 -2445 <br /> Contractor I Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 485184 8898679 5/10/20 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) j e <br /> F . F . # 1016243710 <br /> VR # C24135 BE <br /> 111 . OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATIO <br /> Inspection Method ® Manufacturer Guidelines (Specify) : Veeder Root <br /> Used : <br /> ❑ Industry Code or Engineering Standard (Specify) : ENVIRO 1 <br /> r4s ` N11 a <br /> ❑ Engineered Method (Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages <br /> TANK ID : (By tank number, stored product, etc.) 87 91 Diesel <br /> What is the tank inside diameter? (Inches) 120 120 120 <br /> is the fill piping secondarily contained? ✓❑ Yes ❑ No ® Yes ❑ No ❑✓ Yes ❑ No ❑ Yes ❑ No <br /> Is the vent piping secondarily contained? 0 Yes ❑ No © Yes ❑ No ❑✓ Yes ❑ No ❑ Yes ❑ No <br /> Overfill Prevention Equipment Manufacturer(s) Veeder Root Veeder Root Veeder Root <br /> TLS 350 TLS 350 TLS 350 <br /> What is the overfill prevention equipment response ❑ Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow <br /> when activated? <br /> ❑ <br /> (Check all that apply.) ❑ <br /> Restricts Flow Restricts Flow Restricts Flow ❑ Restricts Flow <br /> ® A/V Alarm ® A/V Alarm ® AIV Alarm ❑ AIV Alarm <br /> Are flow restrictors installed on vent piping? ❑ Yes ❑✓ No ❑ Yes ❑✓ No ❑ Yes ® No ❑ Yes ❑ No <br /> At what level in the tank is the overfill prevention set <br /> to activate? (Inches from bottom of tank.) 18 , 066 91033 91043 <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 90 90 90 <br /> Is the overfill prevention in proper operating condition ® Yes ® Yes ® Yes ❑ Yes <br /> to respond when the substance reaches the <br /> El level? No (Specify in V.) ❑ No (Specify in V.) El No (Specify in V.) El No (Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ® Pass ❑ Fail ® Pass ❑ Fail ® Pass ❑ Fail I ❑ Pass ❑ Fail <br /> V. COMMENTS <br /> Any items marked "Fail' must be explained in this section. Any additional comments may also be provided here. <br /> All Overfills set to 90% . Audio and Visual Working . <br /> Removed All Ball Floats , <br /> VL CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> 1 hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations , Title 23 , <br /> Division 3, Chapter 16, Section 2637 .2 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> If the facility has more components than this form accommodates, additional copies of this page may be attached. <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = International Code Council, AN = Audible and Visual <br />