4.0 FINDINGS <br /> 4.1 Stratigraphy and Field Observations <br /> Dry salt to fine sandy-silts were present in borings CB-1 and CB-2 from surface grade to a <br /> depth of approximately 20 feet Dry to damp sands were encountered from 20 feet to 30 feet <br /> and again from 35 feet to 53 feet Damp silts were present from 30 to 35 feet However, a <br /> gravel layer was noted in CB-2 from approximately 33 to 35 feet Fine sandy silt to clayey <br /> salt was present from 53 feet to 65 feet (total depth) <br /> Hydrocarbon odors were noted in samples from boring CB-1 at depths from 20 feet to 45 <br /> feet and in boring CB-2 at depths from 35 feet to 45 feet Organic vapors were detected by <br /> the PID at concentrations up to 564 ppm (CB2-35) The generalized stratigraphy between <br /> CB-1 and CB-2 is illustrated on Figure 3 <br /> Borings MW-8 and MW-9 penetrated silts from surface grade to 20 feet A silty clay was <br /> encountered in boring MW-9 near ground surface Stratigraphy in boring MW-8 vaned <br /> widely from 20 feet to 53 feet Soils consisted of inter-bedded clays, silts, sands and gravel <br /> Boring MW-9 contained a clay layer from approximately 22 feet to 28 feet, underlain by silt <br /> Fine sandy silt to clayey silt was present in both borings from approximately 53 feet to 75 <br /> feet (total depth) No hydrocarbon odors or organic vapors were detected in borings MW-8 <br /> or MW-9 The boring logs are included in Appendix B <br /> 4.2 Analytical Results of Soil Samples <br /> A total of 16 soil samples were analyzed for TPH as gasoline and BTE&X No petroleum <br /> hydrocarbons were detected in samples from MW-8 or MW-9 TPH as gasoline was detected <br /> in samples CB-1-20 and CBI-35 at 300 ppm and 2,200 ppm, respectively Toluene, <br /> ethylbenzene and xylenes were detected in sample C131-35 at concentrations of 0 14 ppm, <br /> 14 ppm, and 23 ppm, respectively <br /> TPH as gasoline was detected in boring CB-2 at depths of 30 feet and 35 feet (39 ppm and <br /> 450 ppm) Xylene was detected in C132-35 at 15 ppm Xylenes were detected in sample <br /> CB2-40 at a concentration of 0 0054 ppm No benzene was detected in any of the samples <br /> analyzed Figure 3 shows the initial extent of impacted soil from the drilling of MW-2 and <br /> EW-1 Figure 4 shows the extent of remaining impacted soil <br /> Two soil samples were analyzed for total lead Lead was detected in samples CB1-15 and <br /> CB1-20 at concentrations of 12 ppm and 9 ppm, respectively The analytical results of the <br /> soil samples are summarized in Table 2 The laboratory report and chain-of-custody are <br /> included in Appendix C <br /> C�bBa3 Acd1 Semsa I.c <br /> 0-w.5.k.ry'.n 94,11 <br />