Laserfiche WebLink
3.3 Recovery Test Procedures <br /> Each recovery test shall be performed according to the following schedule. <br /> a. Turn pump off at the specified time. <br /> b. Contractor shall measure depth to water and record as follows (t' refers to <br /> time since pump shut off): <br /> 1) Each minute, t' = 1 minutes to t' = 10 minutes. <br /> 2) Each 2 minutes, t' = 10 minutes to t' = 20 minutes. <br /> 3) Each 5 minutes, t' = 20 minutes to t' = 50 minutes. <br /> 4) Each 10 minutes, t' = 50 minutes to t' = 120 minutes. <br /> 3.4 Test Abort Procedures <br /> In the case of failure of the pump operation for a period greater than one <br /> percent (1%) of the elapsed pumping time from t = 0, the test shall be suspended <br /> until the static water level has been attained. <br /> 17 <br />