Laserfiche WebLink
GEOMATRIX <br /> water along the inside of the well casing. Procedures for purging slowly recharging wells are <br /> discussed in Section A3. <br /> A minimum of four well casing volumes or one saturated borehole volume,whichever is <br /> greater,will be removed to purge the well prior to collection of groundwater samples if the well <br /> will be purged with non-dedicated equipment. If a low-flow capacity pump is dedicated in the <br /> well,the micropurge method described in Section AA may be used to reduce the purge volume. <br /> If the well goes dry before four casing volumes are removed, the procedure discussed in <br /> Section A.3 will be followed. The saturated borehole volume is the volume of water in the well <br /> casing plus the volume of water in the filter pack. For a well with a dedicated pump and <br /> packer,a casing volume is defined as the volume of water in the well casing below the inflated <br /> packer. <br /> Periodic observations of turbidity and measurements of temperature,pH,and specific electrical <br /> conductance(SEC)will be made with field equipment during purging to evaluate whether the <br /> water samples are representative of the target zone. Samples will be collected when: (1)a <br /> minimum of four sets of parameter readings have been taken; and(2)the temperature,pH, and <br /> SEC reach relatively constant values, and the turbidity has stabilized. <br /> A.2 Sampling Monitoring Wells <br /> The sampler will wear clean gloves appropriate for the chemicals of concern while collecting <br /> the sample. Samples will be collected directly in laboratory-prepared bottles from the sampling <br /> device. <br /> Each sampling episode or day should generally begin with the well having the least suspected <br /> concentrations of target compounds. Successive wells should generally be sampled in <br /> sequence of increasing suspected concentration. <br /> A Teflon bailer,new disposable bailer, stainless steel positive displacement Teflon bladder <br /> pump with Teflon tubing,or a clean electric submersible pump with low-flow sampling <br /> capacity will be used to collect the water samples for laboratory chemical analysis. <br /> If a bailer is being used to collect the sample, it will be gently lowered into the well below the <br /> point where the purge device was located. Samples will collected in the following order: (1) <br /> volatile organic compounds; (2)semi-volatile organic compounds;(3)metals; (4) other <br /> analytes. <br /> L\Doc_SafeTROTOCOUPROTO-MWAoc SAMPLTNGOFGROUNDWATER MONITORTNGWELLS AND WATER SUPPLY WELI2 <br /> Page 2 of 9 <br /> Revision Date: March 1996 <br />