GEOMATRIX <br /> The field sampler will sign the CHAIN-OF-CUSTODY RECORD and will record the time and <br /> date at the time of transfer to the laboratory or to an intermediate person. A set of signatures is <br /> required for each relinquished/reserved transfer, including transfer within Geomatrix. The <br /> original imprint of the chain-of-custody record will accompany the sample containers. A <br /> duplicate copy will be placed in the project file. <br /> If the samples are to be shipped to the laboratory,the original CHAIN-OF-CUSTODY will be <br /> sealed inside a plastic bag within the ice chest,and the chest will be sealed with custody tape <br /> which has been signed and dated by the last person listed on the chain-of-custody. U.S. <br /> Department of Transportation shipping requirements will be followed and the sample shipping <br /> receipt will be retained in the project files as part of the permanent chain-of-custody document. <br /> The shipping company(e.g.,Federal Express,UPS,DHL)will not sign the chain-of-custody <br /> forms as a receivor;instead the laboratory will sign as a receivor when the samples are <br /> received. <br /> 5.0 EQUIPMENT CLEANING <br /> Bailers,sampling pumps,purge pumps, and other non-dedicated purging or sampling apparatus <br /> will be cleaned before and after sampling each well. Factory new and sealed disposable bailers <br /> may be used for sampling,but may not be reused. Thermometers,pH electrodes,and SEC <br /> probes that will be used repeatedly will be cleaned before and after sampling each well and at <br /> any time during sampling if the object comes in contact with foreign matter. <br /> Purged waters and solutions resulting from cleaning of purging or sampling equipment will be <br /> collected and stored properly for future disposal by the client,unless other arrangements have <br /> been made. <br /> Cleaning of reusable equipment that is not dedicated to a particular well will consist of the <br /> following: <br /> • Bailers-the inside and outside of bailers will be cleaned in a solution of laboratory- <br /> grade detergent and potable water, followed by a rinse with deionized(DI)water. <br /> They may also be steam-cleaned,followed by a DI water rinse. If samples are to be <br /> collected for metals analysis,the Teflon bailer may be rinsed with a pH2 nitric acid <br /> solution followed by a double DI rinse. <br /> • Purge Pumps-All downbole,reusable portions of purge pumps will be steam- <br /> cleaned on the outside. If the pump does not have a backflow check valve,the <br /> I:\Doc_Safe\PROTOCOL\PROTO-MW.doc SAMPLING OF GROUNDWATER MONITORING,WELLS AND WATER SUPPLY WELLS <br /> Revision Date: March 1996 Page 8 of 9 <br />