My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
3091
>
2200 - Hazardous Waste Program
>
PR0526723
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/18/2020 2:10:20 PM
Creation date
5/26/2020 3:04:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0526723
PE
2220
FACILITY_ID
FA0018094
FACILITY_NAME
PROFESSIONAL AUTO REPAIR
STREET_NUMBER
3091
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
11904225
CURRENT_STATUS
01
SITE_LOCATION
3091 N WILSON WAY
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
146
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of hazardous waste violations that have not been <br /> addressed for PROFESSIONAL AUTO REPAIR as of May04 , 2020 . <br /> Open violations from February 07 , 2020 inspection <br /> Violation #608 - Failed to properly manage used oil and fuel filters . <br /> OBSERVATION <br /> 1 . This facility generates drained used metal oil filters . A complete three year bill of lading record for used oil filter <br /> recycling was not observed during the inspection . Bills of lading were not observed for the following date range : <br /> 2/7/2017 - 2/7/2020 . <br /> 2 . Container(s) of used metal oil filters out of compliance with the storage rules were observed on-site . The <br /> following used metal oil filter container(s ) were on -site : <br /> - An open 55-gallon blue steel drum of used plastic and metal transmission filters was observed unlabeled and <br /> missing its lid ring (see photos IMG 0697-8 ) . <br /> - An open 55-gallon black steel drum of used paper oil filters and drained metal oil filters was observed unlabeled <br /> and missing its lid ring ( IMG 0699-700) . <br /> REGULATION GUIDANCE: <br /> Persons generating , transporting , or receiving used metal oil filters shall use a bill of lading to record the transfer of <br /> used oil filters . Bills of lading must indicate generator, transporter, and receiving company names , addresses , <br /> telephone numbers , the quantity and size of used oil filter containers transferred , and the date of transfer . A copy of <br /> each bill of lading must be kept on the premises of the generator, transporter, and receiving facility where the used <br /> oil filters were handled . Copies of bills of lading shall be kept for a period of three years . <br /> ( b) " used oil filters" are defined as filters which contain a residue of used oil and which are exempt from regulation <br /> as a hazardous waste under the scrap metal provision found in federal law. <br /> (c) Used oil filters that meet the conditions of subsection ( b) of this section and are managed and recycled in <br /> compliance with the following requirements shall not be regulated as hazardous waste . <br /> ( 1 ) The filters are drained of free-flowing used oil . For the purposes of this subsection , free-flowing is defined as a <br /> continuous stream of oil exiting the filter when the filter is inverted . Oil exiting drop by drop is not considered to be <br /> free-flowing . However, if the filter is equipped with a device (such as a rubber flap located just inside the filter <br /> opening) which impedes the drainage of used oil from the filter, that device shall be manipulated to allow the oil to <br /> exit the filter freely, or the filter punctured , crushed , opened , drained , or otherwise handled in a manner that will <br /> allow the used oil to exit the filter. <br /> (2 ) The drained used oil filters are transported for purposes of metal reclamation to any of the following : <br /> (A) A smelter or other scrap metal processor where they are recycled or; <br /> ( B) A storage facility or consolidation facility that subsequently transfers the filters to a facility described in paragraph <br /> (A) or (C) of this subsection or; <br /> ( C ) A municipal solid waste incinerator for energy recovery, if the residual casings are subsequently transferred to a <br /> facility described in paragraph (A) of this subsection , or to a storage or consolidation facility that subsequently <br /> transfers the residual casings to a facility described in paragraph (A) of this subsection . <br /> ( 3) The drained used oil filters are accumulated , stored , and transferred in a closed , rainproof container that is <br /> capable of containing any used oil that may separate from the filters placed inside . Drums of used oil filters shall be <br /> sealed during transfer so that used oil will not spill out when they are laid upon their sides . Drums shall be secured <br /> as a load to prevent movement or tipping during transfer. Containers shall be labelled as "drained used oil filters" <br /> ( not as hazardous waste) and show initial date of accumulation or receipt on each container of filters . <br /> (4 ) Storage of less than one ton of used oil filters shall be limited to one year. Storage of one ton or more of used oil <br /> filters is limited to 180 days . <br /> (5 ) Persons generating , transporting , or receiving used oil filters shall use a bill of lading to record the transfer of <br /> used oil filters . Bills of lading must indicate generator, transporter, and receiving company names , addresses , <br /> telephone numbers , the quantity and size of used oil filter containers transferred , and the date of transfer. A copy of <br /> each bill of lading must be kept on the premises of the generator, transporter, and receiving facility where the used <br /> oil filters were handled . Copies of bills of lading shall be kept for a period of three years . <br /> CORRECTIVE ACTION : <br /> 1 . Immediately obtain all missing bill of lading recycling records that can be found . Used metal oil filters not stored , <br /> handled and disposed of according to this section are regulated as hazardous waste. Provide a corrective action <br /> Page 9 of 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.