Laserfiche WebLink
WORK ORDER 9711384 QUALITY CONTROL REPORT PAGE QR-3 <br /> • ANALYSIS Gasoline Oxygenates <br /> MATRIX Water <br /> SAMPLE SURROGATES <br /> SAMPLE TYPE Sample Client LAB ID 9711384 01C INSTR RUN GCMS121971203210000/21/ <br /> INSTRUMENT HP mass spec for Volatiles PREPARED BATCH ID MS12W120597 <br /> UNITS ug/L ANALYZED 12/05/97 DILUTION 1 00 <br /> METHOD <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (X) RPD <br /> ANALYTE RESULT RESULT LIMIT VALUE (X) LOW HIGH RPD (X) LIMIT (X) <br /> 1,2 DCE d4 (surr) 99 1 100 100 99 1 70 130 <br /> Toluene-d8 (surr) 91 8 100 100 91 8 70 130 <br /> Bromofluorobenzene (surr) 97 5 100 100 97 5 70 130 <br /> SAMPLE TYPE Sample Client LAB ID 9711384 02C INSTR RUN GCMS121971203210000/22/ <br /> INSTRUMENT HP mass spec for Volatiles PREPARED BATCH ID MS12W120597 <br /> UNITS ug/L ANALYZED 12/05/97 DILUTION 1 00 <br /> METHOD <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (,T) RPD <br /> ANALYTE RESULT RESULT LIMIT VALUE (X) LOW HIGH RPD (X) LIMIT (X) <br /> 1 2 DCE d4 (surr) 93 5 100 100 93 5 70 130 <br /> Toluene d8 (surr) 111 100 100 111 70 130 <br /> Bromofluorobenzene (surr) 86 8 100 100 86 8 70 130 <br /> SAMPLE TYPE Sample Client LAB ID 9711384 03C INSTR RUN GCMS121971203210000/23/ <br /> INSTRUMENT HP mass spec for Volatiles PREPARED BATCH ID MS12W120597 <br /> UNITS ug/L ANALYZED 12/05/97 DILUTION 1 00 <br /> METHOD <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (X) RPD <br /> ANALYTE RESULT RESULT LIMIT VALUE (X) LOW HIGH RPO (X) LIMIT (1) <br /> 1,2-DCF d4 (surr) 98 8 100 100 98 8 70 130 <br /> Toluene d8 (surr) 97 7 100 100 97 7 70 130 <br /> Bromofluorobenzene (surr) 96 1 100 100 96 1 70 130 <br /> SAMPLE TYPE Sample Client LAB ID 9711384-04C INSTR RUN GCMS121971203210000/24/ <br /> INSTRUMENT HP mass spec for Volatiles PREPARED BATCH ID MS12WI20597 <br /> UNITS ug/L ANALYZED 12/05/97 DILUTION 1 00 <br /> METHOD <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (%) RPD <br /> ANALYTE RESULT RESULT LIMIT VALUE (X) LOW HIGH RPD (%) LIMIT (X} <br /> 1 2 DCE d4 (surr) 101 100 100 101 70 130 <br /> Toluene d8 (surr) 96 0 100 100 96 0 70 130 <br /> Bromofluorobenzene (surr) 91 1 100 100 91 1 70 130 <br /> SAMPLE TYPE Sample-Client LAB ID 9711384 05C INSTR RUN GCMS121971205000000/2/ <br /> INSTRUMENT HP mass spec for Volatiles PREPARED BATCH ID MS12WI20697 <br /> UNITS ug/L ANALYZED 12/05/97 DILUTION 1 00 <br /> METHOD <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (X) RPD <br /> ANALYTE RESULT RESULT LIMIT VALUE (X) LOW HIGH RPD (X) LIMIT (%) <br /> 1 2 DCE d4 (surr) 102 100 100 102 70 130 <br /> Toluene d8 (surr) 95 0 100 100 95 0 70 130 <br /> Bromofluorobenzene (surr) 98 5 100 100 98 5 70 130 <br /> SAMPLE TYPE Sample Client LAB ID 9711384 06C INSTR RUN GCMS121971205000000/3/ <br /> INSTRUMENT HP mass spec for Volatiles PREPARED BATCH ID MS12W120697 <br /> UNITS ug/L ANALYZED 12/06/97 DILUTION 1 00 <br /> METHOD <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (X) RPD <br /> ANALYTE RESULT RESULT LIMIT VALUE (X) LOW HIGH RPD (X) LIMIT (X) <br /> 1,2 DCE d4 (surr) 103 100 100 103 70 130 <br /> Toluene d8 (surr) 101 100 100 101 70 130 <br /> Bromofluorobenzene (surr) 95 5 100 100 95 5 70 130 <br />