Laserfiche WebLink
I <br /> ' F ;�;iic11%.�i12 �IZi'er vreii2r`jZiuf iV�l-bVC�i h <br /> , n <br /> PAGE QR-6 <br /> QUALITY CONTROL DATA <br /> METHOD EPA 8020, 5030 GCFID <br /> AEN JOB NO 9712009 <br /> INSTRUMENT H <br /> MATRIX WATER <br /> Surrogate Standard Recovery Summary <br /> Percent Recovery <br /> Date <br /> Analyzed Client Id Lab Id Fluorobenzene <br /> 12/07/97 VW-1 01 100 <br /> 12/08/97 VW-2d 02 99 <br /> 12/07/97 VW-4 03 94 <br /> 12/08/97 VW-5d 04 97 <br /> 12/07/97 PZ-1 05 100 <br /> 12/07/97 RW-1 06 97 <br /> QC Limits 70-130 <br /> DATE ANALYZED 12/07/97 <br /> SAMPLE SPIKED LCS <br /> INSTRUMENT H <br /> Laboratory Control Sample Recovery <br /> QC Limits <br /> Spike <br /> Added Percent Percent <br /> Analyte (ug/L) Recovery RPD Recovery RPD <br /> Benzene 100 88 16 70-130 20 <br /> Toluene 100 96 17 70-130 20 <br /> Ethylbenzene 100 100 17 70-130 20 <br /> Total Xylenes 300 99 20 70-130 20 <br /> Daily method blanks for all associated analytical runs showed no contamination <br /> at or above the reporting limit <br /> *** END OF REPORT *** <br />