TABLE <br /> Soil Vapor Extraction Data <br /> FIRE STATION #2 <br /> 110 West Sonora Street, Stockton, California <br />' 1[ Date Time Hours Flow(CFM) Vacuum Inlet Outlet <br /> inches of OVM OVM <br /> water DDMV PPMV <br /> 10-11-01 1 pm 0 115 23 175 00 <br /> 10-18-01 2 pm 168 110 20 180 03 <br /> t10-23-01 8 am 276 110 23 180 188 <br /> off-line <br />' 11-02-01 11 am 276 105 24 175 00 <br /> on-line <br /> 11-05-01 9 am 344 110 23 164 00 <br /> 11-28-01 1 30 pm 895 106 34 54 106 <br />' 12-10-01 1 30 pm 1183 105 34 285 64 <br /> 12-27-01 2 pm 1591 110 22 27 01 <br /> lie 01-10-02 10 am 1903 37 89 00 <br /> 02-18-02 1 pm 2815 105 32 28 00 <br /> 03-12-02 12 pm 3342 110 34 20 0 <br /> 04-16-02 11 am 4182 105 36 53 32 <br /> 05-13-02 12 am 4830 105 26 12 0 <br /> 06-11-02 12 am 5502 100 31 0 0 <br /> 07-17-02 9 am 6366 104 34 34 - <br /> 08-20-02 1 12 pm 7182 115 34 <br /> notes <br /> cubic feet pre minute CFM <br /> organic vapor meter OVlvl <br /> parts per million volume ppmv <br /> I <br /> IAdvanced GeoEnvironmental,Inc <br />