Laserfiche WebLink
ANALYTICAL METHODOLOGY <br /> BTEX (Benzene, Toluene, Ethyl Benzene, and Xylenes) by Purge & Trap and <br /> GC-PID <br /> WATER - Method 602 or 8020 <br /> A 5 ml sample volume, or 5 ml of a suitable dilution, 2s purged on a <br /> suitable purge and trap system with helium. The purged sample is analyzed <br /> on a Gas Chromatograph equipped with a Photoionization Detector (PID). A <br /> packed column is used to separate the compounds. <br /> SOIL - Method 8020 <br /> A 10 gram, or other appropriate aliquot of soil, 2s weighed into a clean <br /> VOA vial. Soils received 2n brass core tubes are sampled by discarding 2-5 <br /> centimeters of soil from each end of the tubes (this 2s done to reduce the <br /> poss2bil,ity of analyzing a portion of soil that has been exposed to sampling <br /> technique contamination). Equal aliquots of soil are then removed from <br /> each end of the tube and combined in the VOA vial. Soil 2r] bars or bags <br /> 2s aliquoted using a similar technique, which discards exposed sample <br /> surfaces. A 10 ml, or other appropriate volume of methanol, 2s added to <br /> the soil and the soil 2s shaken with the solvent. 100 ul of the extract, or <br /> a reduced aliquot or volume of a suitable d2luUon, 2s injected 2nto 5 ml of <br /> laboratory blank water and analyzed by the same technique used for water <br /> sa mples. <br />