Laserfiche WebLink
1 <br />' Site Background Information <br /> • SUTTER OFFICE CENTER <br /> 1 242 North Sutter Street, Stockton, California <br />' at a maximum concentration of 5,300 4g/1 (CPT1-150) BTEX compounds were detected in <br /> CPT1-150, CPT2-150, and CPT5-150 at maximum concentrations of 35 µg/I benzene, 590 µg/l <br /> toluene, 360 µg/1 ethylbenzene, and 1,700 µg/1 xylenes in sample CPT2-150 In addition, the fuel <br />' additive 1,2-DCA was detected in sample CPT2-150 at 2 8 µg11 No other analytes were detected in <br /> the samples analyzed <br />' An additional grab ground water sample (CPT2-185) was collected at a depth of 185 feet bsg, <br /> approximately 25 feet below the limit of CPT soil data TPH-g was detected in this sample at a <br /> concentration of 130µg/1 In addition,BTEX compounds were detected at concentrations of 17 µg/1 <br /> benzene, 2 3 µg/1 toluene, and 2 2 ggll xylenes No other analytes were detected <br /> rCONCLUSIONS <br /> The following conclusions were drawn from the results of this investigation <br /> • The site stratigraphy is composed predominantly of fine-grained soil consisting of silt,clayey <br /> silt, silty clay, and clay, with the exception of five significant sand lenses at depths of <br /> approximately 50 feet bsg, between 60 and 75 feet bsg, between 95 and 110 feet bsg, <br /> between 120 and 130 feet bsg, and between 140 and 160 feet bsg CPT pore pressure <br /> dissipation tests in the sandy silt, sand, and gravelly sand indicated that hydraulic <br /> conductivities were typical for sand mixtures <br /> • TPH-g and BTEX were detected in soil at low concentrations at 55 feet bsg,but at significant <br /> concentrations at 78 feet bsg Based on the vertical distribution of contaminants in soil from <br /> the present and previous site investigations, AGE delineated two distinct zones of <br /> contaminated soil in fine-grained soil (HUI) between 30 and 40 feet bsg beneath the <br /> Chevron (northeastern-most) former dispenser island, and in fine-grained soil (HU3) at <br /> 80 feet bsg The soil contamination at 30 to 40 feet bsg, which included diesel as well as <br /> gasoline products,may have originated from the overlying former Chevron dispenser island <br /> area However,based on the available data,the source for the deeper contamination at 80 feet <br /> bsg is uncertain, the former Standard Oil USTs cannot be ruled out <br /> • Petroleum hydrocarbons were detected in grab ground water samples collected from the <br /> northeastern portion of the site, in the area of CPT-1, CPT-2, and CPT-5, to approximately <br /> 180 feet bsg Based on the vertical distribution of contaminants in ground water from the <br /> present and previous site investigations, the highest concentration of contaminants appears <br /> to be at between the upper ground water surface at boring A/MW-1 and at 40 and 60 feet bsg <br /> in the area of CPT-1 and CPT-2 The concentrations of contaminants appear to decrease <br /> vertically toward a minimum in clay-nch, fine-grained soil at a depth between 80 and <br /> 100 feet bsg However, petroleum hydrocarbons increase again below 100 feet bsg, to high <br /> concentration between 11,000 µg/1 and 14,000 µg/1 TPH-g at depths between 120 and <br /> Advanced GeoEnvaronmentai,Inc <br />