Laserfiche WebLink
11 � <br /> GROUNDWATER MONITORING AND SAMPLING REPORT <br /> BP Oil Company Service Station No. 17.7.94E <br /> 2375 Tracy Boulevard <br /> Tracy, California <br /> Project No. 10-085-04-Q03 <br /> November 11, 1994 <br /> r <br /> INTRODUCTION <br /> 5 <br /> This report presents the results and findings of the September 13, 1994 groundwater <br /> monitoring and sampling conducted by Alisto Engineering Group at BP Oil Company Service <br /> Station No 11194, 2375 Tracy Boulevard, Tracy, California A site vicinity map is shown in <br /> Figure 1 <br /> FIELD PROCEDURES <br /> Field activities were performed in accordance with the procedures and guidelines of <br /> San Joaquin County Public Health Services and the California Regional Water Quality <br /> Control Board, Central Valley Region <br /> Before purging and sampling, the groundwater level in each well was measured from a <br /> permanent mark on top of the casing to the nearest 0 01 foot using an electronic sounder <br /> The depth to groundwater and top of casing elevation data were used to calculate the <br /> groundwater elevation in each well in reference to mean sea level The survey data and <br /> groundwater elevation measurements collected to date are presented in Table 1 <br /> Before sample collection, each well was purged of 3 casing volumes, while recording field <br /> readings of pH, temperature, and electrical conductivity Groundwater samples were <br /> collected for laboratory analysis by lowering a bottom-fill, disposable bailer to lust below the <br /> water level in the well The samples were transferred from the bailer into laboratory- <br /> supplied containers The water sampling field survey forms are presented in Appendix A <br /> SAMPLING'AND ANALYTICAL RESULTS <br /> The results of monitoring and laboratory analysis of the groundwater samples for this and <br /> previous quarters are summarized in Table 1 The potentaometric groundwater elevations <br /> interpreted from the results of this monitoring event are shown in Figure 2 The results of <br /> groundwater analysis are shown in Figure 3 The laboratory report and chain of custody <br /> record are presented in Appendix B <br />