Laserfiche WebLink
SITE PLAN <br /> MAY, 2020 <br /> EIGHT I L E ROAD OWNER REVISED SffE PLA <br /> App{icaol 2 0 <br /> SGAL 1' _ 40 STEWART GONG f <br /> 4084 CHIAVARI WAY . - <br /> SEE NOTE, 8 SEE NOTE 4 E/P MANTECA, CA 95337 <br /> ' --- --- _ _ - ---- ---- ----- -- --- ---_-_- ----- -----__- (916) 813-5285 <br /> E GWEVR <br /> E/P <br /> DILLON & MURPHY <br /> - / --�� — --- -- P.O. BOX 2180 <br /> 215' i 2-18" CULVERTS (EX) 847 N. CLUFF AVENUE, SUITE A2 <br /> ODI, <br /> j s yI i------ i —� � ((209 209 33 95241 <br /> ) 334-6613 <br /> _ _ SEE NOTE 12 W Y w y <br /> y W r---SEE NOTE 10 i i Y W j NOTES <br /> \\l -_�••/ 1. APN: 086-070-09 <br /> W 2. WATER: PRIVATE WELL <br /> y r 3. SANITARY SEWER: SEPTIC <br /> SEE NOTE 5 SEE NOTE 9 8't <br /> Y O4. STORM DRAINAGE: NATURAL DRAINAGE <br /> zi SEE NOTE 2 <br /> 5. SITE ADDRESS: 4946 E. EIGHT MILE ROAD STOCKTON, CA <br /> v ,• 6. FLOOD ZONE: ZONE X, MAF N0, 0607 <br /> y _7C0320F DATED OCTOBER 16, 2009. <br /> 53't y �1 i 7. ALL IMPROVEMENTS ARE EXISTING, UNLESS NOTED. <br /> I 1 <br /> 4 <br /> ----- ` ' <br /> W w • I REMOVE 253 S.F. <br /> .;. +y ---- OF ASPHALT <br /> CONCRETE <br /> REMOVE LANDSCAPING L-PROP. 9X20' I I NOTES: LEGEND <br /> AS NECESSARY TO PARKING STALLS III <br /> CONSTRUCT DRIVEWAY. I `i <br /> ACS�EPTiG/ , 11, AB AGGREGATE BASE <br /> EX SEPTIC/ z 1. EXISTING 1440 SF BUILDING TO BE USED FOR TRAINING. AC ASPHALT CONCRETE <br /> LEACI� w — EX. WELL 2. EXISTING 1740 SF HOUSE TO BE USED AS A FIRE FIGHTER RESIDENCE. BLDG. BUILDING <br /> 100% LEACH FIELD <br /> 3. EXISTING 2700 SF BUILDING TO BE USED FOR APPARATUS STORAGE. CONC. CONCRETE <br /> REPLACEMENT AREA , 4. EXISTING 30' WIDE DRWY TO BE EXPANDED 10' EAST. EX. EXISTING <br /> 40'± 5. 170' TO NEIGHBOR'S SEPTIC, 70' TO WELL. R/W RIGHT—OF—WAY <br /> 100% LEACH FIELD 6. 90' TO NEIGHBOR'S SEPTIC, 25' TO WELL. <br /> REPLACEMENT AREA L — 7. THERE ARE NO OAK TREES TO BE REMOVED FROM THIS SITE. <br /> 8. PROPOSED 20' WIDE DRIVEWAY. LANDSCAPE <br /> 9. PROPOSED ADA BATHROOM. - <br /> 10. PROPOSED ADA ENTRY. <br /> 11. THERE ARE ASSORTED LANDSCAPING TREES ALONG -HE EAST <br /> AND WEST PROPERTY LINES. EX. AC <br /> 12. PROPOSED ADA PARKING. <br /> 13. LEACH FIELD REPLACEMENT AREA WILL BE LOCATED IN COMPLIANCE <br /> WITH COUNTY STANDARDS AND SETBACKS. EX. CONC. <br /> 14. THE PROPOSED NUMBER OF EMPLOYEES PER SHIFT IS THREE. <br /> BARE GROUND THE SEPTIC SYSTEM AND LEACH FIELD ARE SIZED APPROXIMATE. <br /> 15. DISPOSAL LEACH FIELD TO BE BARRICATED SO NO TRAFFIC DRIVES PROPOSED COMPACTED BASEROCK <br /> ON THEM OR PARKS ON THEM. STORAGE ON THE LEACH FIELD 1S ALSO <br /> NOT ALLOWED. <br /> EX. TREE <br /> EX. CONTOUR <br /> LANDSCAPE <br /> PROPOSED AC =S <br /> E3 mi <br /> SEE NOTE i PROPOSED CONS,. <br /> EIGHT MILE RD. <br /> 99� <br /> C) <br /> U DILLON & MURPHY <br /> PROJECT 5I TE <br /> ENGINEERING <br /> -+- 847 N. CLUFF AVENUE <br /> DILLON & MURPHY <br /> SUITE A-2, LODI, CA 95240 <br /> E N G { N E E R { N G (209} 334-6813 <br /> MORA,DA LANA 4946 E. EIGHT MILE ROAD <br /> * MOSHER SLOUGH 1S 4000'± FROM PROPERTY LINE. <br /> � STOCKTON,CA <br /> WCINITY MAP <br /> ^� - SITE FLAN <br /> r <br /> 215' SAN JOAQUIN COUNTY, CALIFORNIA <br /> MARCH, 2020 <br /> REV. NO. [ESCRIPTION DATE SCALE: 1"= 40' SHEET t, <br /> z <br /> DRAWN BY: JM 1 <br /> 4. <br /> DESIGNED BY: OF 1 SHEETS °i- <br /> CHECKED BY: JM JOB N0. <br /> AS BUILT BY: XXXX <br /> c; <br />