My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0081896
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARGARETE
>
0
>
4200/4300 - Liquid Waste/Water Well Permits
>
SR0081896
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/29/2020 12:04:38 PM
Creation date
5/29/2020 12:00:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
SR0081896
PE
4222
STREET_NUMBER
0
STREET_NAME
MARGARETE
STREET_TYPE
WAY
City
RIPON
Zip
95366
APN
24506039
ENTERED_DATE
3/16/2020 12:00:00 AM
SITE_LOCATION
0 MARGARETE WAY
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
oP°u�N c* <br /> SAN J O A Q U IN Environmental Health Department <br /> COUNTY <br /> Greatness grows here. <br /> PERCOLATION TEST/SOIL PROFILE INSPECTION CHECKLIST <br /> SJC Ordinance Code,Title 9,Section 9-1105.2 <br /> EHD Policy for Percolation Test Procedure 98-01 <br /> Site Location: Date: q IP4�-z c) <br /> Test Performed by: Permit#: PAM <br /> SITE MAP <br /> Includes perc test and soil profile locations with accurate measurements from a fixed reference point(must be able to locate <br /> the test hole areas in the future). Perc/soil profile holes must meet distance setbacks as noted in the sewage standards for <br /> septic system locations. Percolation test holes and soil profile pits must be conducted in the area proposed for future septic <br /> systems. <br /> Notes any changes in elevation on the subject property. <br /> Notes all water wells. <br /> Notes all man-made features(septic sstems, drives, barns,outbuildings, animal pens,etc. <br /> Notes all natural features(ephemeral drainage courses, large stands of trees, ponds, rivers,etc. <br /> PERC TEST PREPARATION PROTOCOL <br /> Date and time of test hole preparation. <br /> Diameter and depth of test hole 4" 12"diameter and 36"-42"depth). P4 jepA <br /> Dimensions and depth of deep test hole 4"-12"diameter and 42"-25'or minimum 10'above seasonal high water table). <br /> Test hole preparation(scoring of sidewalls, removal of loose material). <br /> Weather conditions at time of testing (raining,windy, etc. wn ? <br /> Soil type and condition encountered in test hole. Jw- t <br /> Addition of 2"of course sand or fine gravel to test hole. <br /> Pre-soak by addition of minimum 12"of water over gravel 24-hours before test). <br /> PERC TEST CONDITIONS, MEASUREMENTS,AND REPORTING <br /> Condition of test hole after the 24-hour re-soak amount of water remaining in the hole,any soil sloughing noted). <br /> Correct amount of water used to refill hole 6"over gravel). Documented on the recorktion sheet. <br /> escri tion of type of perc test procedure used based on conditions Procedure#1,411r#3). <br /> Accurate recordings of drop and refill of water in same measurements. <br /> Same fixed reference point used for each reading. Description of reference point used to be included in the final report. <br /> Math calculations checked for accuracy. <br /> Beginning and end measurements of the last reading verified by REHS.All above reviewed and verified by REHS. <br /> SOIL PROFILE <br /> Description of the date, time, and protocol used to prepare soil profile pit. <br /> Description of soil profile pit including depth and dimensions. <br /> Soil lithology descrPibed b appropriate professional using indust standard protocol. <br /> COMMENTS / <br /> tlr_C <br /> REHS Name: 1 Dom- <br /> Calculations Examples: <br /> Last drop reading=.07'over 30 minutes time. Last drop reading=1.2'over 10 minutes time. <br /> .07'x 12"=.84"(convert from feet to inches) 1.2'x 12"=14.4"(convert from feet to inches) <br /> 30 minutes=.84"=35.7 minutes/inch 10 minutes--, 14.4"=.69 minutes/inch <br /> EHD 4200-xx 8-1-2018 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.